NEP BDM-250-208A Installation And Operation Manual Download Page 11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9. WARRANTY AND PRODUCTION INFORMATION 

What d

o

es this warranty c

o

ver and h

o

w l

o

ng d

o

es it last?   

This Limited Warranty is provided by Northern Electric & Power Co. Ltd (NEP) and 

covers defects in workmanship and materials in your BDM-250 Grid-Tied Inverter. This 

Warranty Period lasts for 10 years from the date of purchase at the point of sale to 

you, the original end user customer, unless otherwise agreed in wri

ng. You will be 

required to demonstrate proof of purchase to make warranty claims.   
This Limited Warranty is transferable to subsequent owners but only for the 

unexpired por

on of the Warranty Period. Subsequent owners also require original 

proof of purchase as described in "What proof of purchase is required?"   

What will NEP d

o

?   

During the Warranty Period, NEP will, at its op

on, repair the product (if economically 

feasible) or replace the defec

�v

e product free of charge, provided that you no

fy NEP 

of the product defect within the Warranty Period, and provided that NEP through 

inspec

on establishes the existence of such a defect and that it is covered by this 

Limited Warranty.   
NEP will, at its op

on, use new and/or recondi

oned parts in performing warranty repair 

and building replacement products. NEP reserves the right to use parts or products of 

original or improved design in the repair or replacement. NEP repairs or replaces a 

product, its warranty con

nues for the remaining por

on of the original Warranty 

Period or 90 days from the date of the return shipment to the customer, whichever is 

greater. All replaced products and all parts removed from repaired products become the 

property of NEP.   

H

o

w d

o

 y

o

u get service?   

If your product requires troubleshoo

ng or warranty service, contact your merchant. If 

you are unable to contact your merchant, or the merchant is unable to provide service, 

contact NEP directly at:   

N

o

rthern Electric & P

o

wer C

o

. Ltd   

Address

NO.1 Anhe Rd Tsingtao Export Processing Zone, Tsingtao, China 266113   

Ph

o

ne

+86 532 87963900        

Fax

+86 532 81100917   

What d

o

es this warranty n

o

t c

o

ver?   

Claims are limited to repair and replacement or if in NEP's discre

on that is not 

possible, reimbursement up to the purchase price paid for the product. NEP will be 

liable to you only for direct damages su

ered by you and only up to a maximum 

amount equal to the purchase price of the product.   
This Limited Warranty does not warrant uninterrupted or error-free opera

on of the 

product or cover normal wear and tear of the product or costs related to the removal, 

installa

on, or troubleshoo

ng of the customer's electrical systems. This warranty

 

MODEL

 

BDM-250-LV

INPUT(DC) 

Max Recommended PV Power (Wp) 

285 

Vmax PV (absolute maximum) (Vdc) 

60 

PV Input Opera

ng Voltage Range (Vdc) 

22-55 

Maximum Opera

ng PV Input Current (Adc) 

12 

MPPT Tracking Accuracy 

>99.5% 

Isc PV (absolute maximum) (Adc) 

14 

Maximum Inverter Backfeed Current to the Array (Adc) 

OUTPUT(AC) 

Rated AC Output Power (W) 

220 

Nominal Power Grid Voltage (Vac) 

127 

Current (maximum con

nuous) (Aac) 

1.73 

Current (inrush) (Peak and Dura

on) 

12A, 15us 

Nominal Frequency (Hz) 

60 

Power Factor (cos phi, 

xed) 

>0.99 

Maximum Output Fault Current (Aac) 

4.2A peak 

Maximum Output Overcurrent Protec

on (Aac) 

10 

Maximum Number of Units Per Branch 

SYSTEM 

EFFICIENCY 

Peak E

ciency 

96.30% 

CEC E

ciency 

95.0% 

Night Time Tare Loss (Wp) 

0.17 

PROTECTION 

FUNCTIONS 

Over/Under Voltage Protec

on 

Yes 

Over/Under Frequency Protec

on 

Yes 

An

-Islanding Protec

on 

Yes 

Over Current Protec

on 

Yes 

Reverse DC Polarity Protec

on 

Yes 

Overload Protec

on 

Yes 

GFDI 

Integrated 

Protec

ve Class 

IP Ra

ng per Part 1 

IP67 

OTHER 

PARAMETERS 

Environment Temperature 

-40

 ~ +65

 

Environment Category 

Indoor and outdoor 

Wet Loca

on 

SUITABLE 

Pollu

on Degree 

PD 3 

Environment Humidity 

100%, condensa

on 

Maximum Al

tude 

2000 M 

Overvoltage Category 

II(PV), III (AC MAINS) 

Display 

LED LIGHT 

Communica

ons 

POWERLINE 

Dimension (D-W-H mm) 

230*138*35 

Weight(Kg) 

Product Safety Compliance 

UL 1741     

CSA C22.2 No. 107.1

 

Grid Code Compliance* (Refer to the label for the 

detailed grid code compliance)

 

 

IEEE 1547 

 

17

16

Summary of Contents for BDM-250-208A

Page 1: ... 9 Meander Grove Cameron Park NSW2285 China Address No 1 Anhe Rd Tsingtao Export Processing Zone Tsingtao China 266113 TEL 86 532 87963900 FAX 86 532 81100917 SAA 122309 N136 BDM 250 240A BDM 250 AU BDM 250 LV BDM 250 208A BDM 250 EU Installa on and Opera on Manual ...

Page 2: ...ocedure Step 1 Install the AC Branch Circuit Junc on Box Step 2 A ach the BDM 250 to the Racking Step 3 Connect the BDM 250 Wiring Harnesses Step 4 Ground the System Step 5 Complete the connec on map and connect the PV Modules 5 COMMISSIONING 6 OPERATING INSTRUCTIONS 7 TROUBLRSHOOTING MAINTENANCE 8 SPECIFICATION 9 WARRANTY AND PRODUCTION INFORMATION WARRANTY CARD 01 02 02 02 02 02 03 03 04 04 04 0...

Page 3: ...ommunity and powered by electricity from solar wind and micro turbines Outside China the company has opera on offices in Chicago U S and Vancouver Canada The technology founders of the company are well known experts in the fields of power electronics automa c control signal processing and communica ons Each of the founders has mul ple U S and world patents in their specialty areas They received Ph D ...

Page 4: ...STALLATION SHOULD BE DONE BY CERTIFIED ELECTRICIAN BESIDES THE CABLE CONNECTORS NOTHING INSIDE THE INVERTER SHOULD BE MODIFIED ALL INSTALLATION SHOULD FOLLOW THE LOCAL ELECTRIC CODES FURTHER PROTECTION ON THE AC WIRING FROM THE INVERTERS SHOULD BE PROVIDED AND MAY BE REQUIRED BY LOCAL AND NATIONAL WIRING REGULATIONS THIS PROTECTION IS LIKELY TO INCLUDE RESIDUAL CURRENT DEVICES EARTH FAULT MONITORS...

Page 5: ...rranty does not cover acts of God such as lightning strikes and since lightning strikes can occur anywhere it is best prac ce to install surge protec on as part of any solar installa on Installa on of surge protec on devices should follow vendor instruc ons Installa on Procedure WARNING DO NOT CONNECT BDM 250 TO THE UTILITY GRID OR ENERGIZE THE AC CIRCUIT S UNTIL YOU HAVE COMPLETED ALL OF THE INST...

Page 6: ...roximately six inches long and are terminated with single pole connectors The AC connectors are oppositely sexed so that mul ple inverters can be connected to form one con nuous AC branch circuit 1 Orient the first BDM 250 in each branch with its male connector facing the junc on box The junc on box AC interconnect cable has a female connector The BDM 250 can be mounted with either side facing up t...

Page 7: ...area Refer to local regula on for minimum size requirement for ground conductor size Step 5 Complete the connec on map and connect the PV Modules BDM 250 connec on Map is a diagramma c representa on of the physical loca on of each BDM 250 in your PV installa on The virtual array in NEP micro inverter gateway BDG 256 is created from the map you create Complete the connec on map Each BDM 250 has a r...

Page 8: ...e BDM 250 is powered on when sufficient DC voltage from the module is applied The status LED will start flashing a er sufficient DC power is applied as an indica on that the BDM 250 is live Status standby The LED light is on by 2 second and off by 2 seconds Status producing power The LED light is on by 1 second and off by 1 second Status producing power and communica ng with BDG 256 The LED light is on ...

Page 9: ...YOUR DISTRIBUTOR FOR MAINTENANCE Disconnec ng a BDM 250 from the PV Module To ensure the BDM 250 is not disconnected from the PV modules under load adhere to the following disconnec on steps in the order shown 1 Disconnect the AC by opening the branch circuit breaker 2 Disconnect the first AC connector in the branch circuit 3 Cover the module with an opaque cover 4 Using a DC current probe verify t...

Page 10: ...ent to the Array Adc 0 OUTPUT AC Rated AC Output Power W 220 Nominal Power Grid Voltage Vac 230 Current maximum con nuous Aac 1 0 Current inrush Peak and Dura on 12A 15us Nominal Frequency Hz 50 Power Factor cos phi fixed 0 99 Maximum Output Fault Current Aac 2 2A peak Maximum Output Overcurrent Protec on Aac 6 3 Maximum Number of Units Per Branch 15 SYSTEM EFFICIENCY Peak Efficiency 96 30 CEC Efficien...

Page 11: ...xport Processing Zone Tsingtao China 266113 Phone 86 532 87963900 Fax 86 532 81100917 What does this warranty not cover Claims are limited to repair and replacement or if in NEP s discre on that is not possible reimbursement up to the purchase price paid for the product NEP will be liable to you only for direct damages suffered by you and only up to a maximum amount equal to the purchase price of t...

Page 12: ...ODUCT AND IS WHERE PERMITTED BY LAW IN LIEU OF ALL OTHER WARRANTIES CONDITIONS GUARANTEES REPRESENTATIONS OBLIGATIONS AND LIABILITIES EXPRESS OR IMPLIED STATUTORY OR OTHERWISE IN CONNECTION WITH THE PRODUCT HOWEVER ARISING WHETHER BY CONTRACT TORT NEGLIGENCE PRINCIPLES OF MANUFACTURER S LIABILITY OPERATION OF LAW CONDUCT STATEMENT OR OTHERWISE INCLUDING WITHOUT RESTRICTION ANY IMPLIED WARRANTY OR ...

Page 13: ...d 1781 Riverview Ave Tracy CA 95377 Australia Address 9 Meander Grove Cameron Park NSW2285 China Add No 1 Anhe Rd Tsingtao Export Processing Zone Tsingtao China 266113 TEL 86 532 87963900 FAX 86 532 81100917 ...

Reviews: