IEC60068-2-27)
Certification
CE/FCC Class A, according to EN 55022 & EN
* The maximal power consumption is measured in Max. Performance Mode with 100% CPU loading applied using
Passmark® BurnInTest™ v7.0. For detail testing criteria, please contact Neousys Technology
** For sub-zero operating temperature, a wide temperature HDD drive or Solid State Disk (SSD) is required.
1.2.3 Specification of Isolated DIO
Isolated Digital Input
No. of Channel
4-CH Isolated Digital Input Channels
Logic Level
Logic High: 5 to 24V
Logic Low: 0 to 1.5V
Isolated Voltage
2500 Vrms
Input Resistance
2.4k
Ω
Operation Mode
Polling I/O, Change-of-State Interrupt
Isolated Digital Output
No. of Channel
4-CH Isolated Digital Output Channels
Sink Current
(per channel)
100 mA (sustained loading)
250 mA (peak loading)
Isolated Voltage
2500 Vrms
Operation Mode
Polling, Change-of-State Interrupt
Output Type
Power Analog Device iCoupler®
Operation Mode
Polling I/O and Change-of-State interrupt for DI