Neonode® Touch Sensor Module User's Guide
Getting started with Touch Sensor Module Evaluation
https://support.neonode.com
16
upwards. Make sure the direction is straight into the connector and the pads have reached the end of
the connector.
c.
Make sure the connector pads of the FPC cable are facing downwards, towards interface board. The
sensor module risks damage if the FPC cable is connected in wrong direction.
d.
Press down the flip lock.
2.
Connect the FPC cable to the sensor module:
a.
Place the sensor module so that the module's connector pads are facing downwards (steel surface
upwards).
b.
Insert the sensor module into the connector on FPC cable (yellow piece of PCB of the FPC connector
still facing upwards).
c. Make sure the direction of the pads is straight into the connector, and the pads have reached the
end of the connector.
3.
Connect a USB cable with a Micro USB type B connector to the interface board.
4.
Make sure no object is within the touch active area of the sensor module before connecting power through
USB. The sensor module calibrates itself when powered on and an object within the touch active area may
interfere with the calibration.