SET THE CH/Z1 AND HW/Z2 PROGRAMMING
On/Off periods
Default schedule
Two On/Off periods settings
Period 1
Start at 06:30
am
End at 08:30
am
Period 2
Start at 05:00
pm
End at 10:00
pm
Three On/Off periods settings
Period 1
Start at 06:30
am
End at 08:30
am
Period 2
Start at 12:00
pm
End at 02:00
pm
Period 3
Start at 05:00
pm
End at 10:00
pm
1- Move the Programming slider to posi-
tion .
All days of week are solid. Underscore
DQG<HV1RDUHÁDVKLQJ
4- Press or to increment/de-
FUHPHQWWKHÀUVW2Q2IISHULRG
end time.
7KHQSUHVV<HVWRFRQÀUP
5- Repeat for the second On/Off
period and for the third On/Off
period.
(Please refer to the advanced
installer settings on Installation
instruction to enable the third
On/Off period).
2- Press
if you want to set an
other day of the week. Under-
score moves under the other
days. Then press
to program
the underscored day.
3- Press or to increment/de-
FUHPHQWWKHÀUVW2Q2IISHULRG
start time.
Then
press
WRFRQÀUP
7- Slide the programming slider
to position
WRFRQÀUPDQG
program the second channel.
6- The current program can be
copy to the next days. Press
Yes to copy or No to program
manually the next day.
8- Repeat the previous step to
program On/Off period for HW/
Z2.
9-
:KHQÀQLVKHGPRYHWKH
program slider to
position to
FRQÀUP
PROGRAMMING
Note : The unit is already set with correct date and time. Should program-
mer need reseting for any reasons, please see instructions on
page 3
.
OPERATING
MODE SELECTION AND DESCRIPTION
Mode sliders sequences for CH/Z1 and HW/Z2:
Constant
all day
auto
off
Constant: Permanent ON mode.
The system is permanently turned
ON.
All day: The system turn ON from the
ÀUVW2QSHULRGVWDUWWLPHXQWLOWKH
last Off period end time of the
current day.
Auto: Automatic mode. The unit is
controlling to the programming that
have been selected
(refer to "Pro-
gramming" section page 2).
Off: Permanent Off mode. The
system stays Off permanently. The
boost mode can be still used.
Note:
- The Programming slider must be in the
position.
- There will be a slight delay between pressing
and activation of
the relay.
BOOST is cancelled by pressing again on Boost or movement of sliders.
When BOOST is running the end of Boost period is shown for each system.
BOOST
BOOST will work from any running mode.
BOOST is entered by pressing
button for corresponding system (CH/
Z1 or HW/Z2).
Press 2 times to set 2 hours and 3 times to set 3 hours.
BOOST: Boost mode is a temporary
mode which allows you to switch
ON for 2 or 3 hours. At the end of set
period the device will revert to its
prior setting.
constant
all day
auto
off
constant
all day
auto
off
off
ff
Advance: advance mode is a
temporary mode which allows you
to switch ON the system in advance,
until the next On/Off period end
time.
Press
button of corresponding
channel to activate this mode.
Press again
button to disable it
before the end.
constant
all day
auto
off
constant
all day
auto