17
5.2.2. Production level selection
To select the desired production level, press the “
” [2] / “
” [2] keys until the production level light blinks. The system information screen [17] will
display the value of the production scale light [1]. The system will set its production to the desired level after a few seconds.
Fig. 24
In normal conditions, the production value [1] should be the same as the programmed value [17]. However, if the salt level in the water is outside the
permitted range (“HIGH SALT” or “LOW SALT” [9] alarms on), or there is a problem in the electrolysis cell (“ELECTRODES” [8] alarm on), the
production value [1] could be lower than the programmed and displayed value [17].
WINTER Mode:
during periods of low water temperature select a production level [10] in the 50-60% range.
5.2.3. Salinity test
The DOMOTIC Series systems have an integrated system to detect the salinity level of pool water. To run the test, press the “SALT TEST” [4] key.
During the test, the production light will range from 20%-80% of the salinity scale [10], alternately displaying “SALT” and “TEST” on the system
information screen [17]. Once the test is completed, the light will blink for a few seconds on the scale [1] on the detected salinity value (see Fig. 25):
low, normal & high. The equipment will return to normal operating mode after a few seconds.
Fig. 25
The system might show lower than actual salt levels if the temperature falls beneath 20
C (68 °F).
Summary of Contents for NEO-12
Page 2: ......
Page 5: ...3 3 DATASHEET...
Page 6: ...4...
Page 7: ...5 Fig 1...
Page 9: ...7 4 3 Electrical connections...
Page 10: ...8...
Page 14: ...12 4 7 Connection PoolStation...
Page 18: ...16 Fig 23 System programming flow sheet...
Page 29: ...27 7 1 3 REPLACEMENT AND CLEANING THE LAMP U V...
Page 30: ...28...
Page 31: ...29...