NEO NEOEDS01Z Quick Start Manual Download Page 3

Safety Warning for Batteries 

The product contains batteries. Please remove the batteries when the device is not used. Do not mix 
batteries of different charging level or different brands. 

Installation 

Door Sensor Installation - Option One 

 

 
Disassemble the door sensor main body and take out battery, fix the main body on the door with 
screws. 
Disassemble the door sensor deputy body and fix it on the corresponding door frame position 
 

 

Option Two

 

Put the sticker on the bottom of door sensor then fix it on the wall. 
 

 

NOTE: 

When installing door sensor, door sensor deputy body must be installed on the bulge side of 

the door sensor main body. 

1.When install door sensor, the distance between main body and deputy body should be less than 
2cm in the state of door closed. 
2.When door is closed, that is to say, distance between main body of door sensor and deputy body is 
less than 2cm, app would display door is closed. 
3.When door is opened, that is to say, distance between main body of door sensor and deputy body is 
more than 2cm, the app would display the door is opened. Through gateway, door sensor can 
associate with ip-camera to take pictures and record video, siren to alarm. 
4.Make sure door sensor is placed in the Z-Wave network range of gateway. 

 

 

Summary of Contents for NEOEDS01Z

Page 1: ...ke sure the internal battery is fully charged 1 Remove the sensor cover 2 Make sure the sensor is powered 3 Set Z Wave controller or Z Wave gateway into inclusion mode Refer to the controller or gatew...

Page 2: ...applications All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network In the front casing there is button that is used to ca...

Page 3: ...installing door sensor door sensor deputy body must be installed on the bulge side of the door sensor main body 1 When install door sensor the distance between main body and deputy body should be les...

Page 4: ...or 10 15s then door sensor would be restored to factory default settings Meanwhile LED lights would flash red colour 5 times on and off alternately 5 Under the normal state LED lights would keep off s...

Page 5: ...ugh the advanced parameters no 1 and 2 This Group Support BASIC_SET 3 5 GROUP 3 allows for Send Notification to associated devices in this group This Group Support NOTIFICATION_REPORT 4 5 GROUP 4 allo...

Page 6: ...tion Sensor Network Operation Reporting Sleeping Slave Z Wave Version 6 51 06 Certification ID ZC10 16055076 Z Wave Product Id 0x0258 0x0003 0x1082 Sensors Open Closed Binary Color White Firmware Upda...

Page 7: ...tral organizer of the network It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the...