19
www.neo-tools.com
For Continuity Test:
When the resistance is between 30 and 100 , the buzzer may sound or may not sound. When the resistance is
more than 100 , the buzzer won’t sound.
AC Current(ACA): Auto Range
Range
Resolution
Accuracy
2A
0.001A
≤0.4A: ± (5%+20)
>0.4A: ± (4%+10)
20A
0.01A
≤4A: ± (4%+10)
>4A: ± (3%+8)
200A
0.1A
± (2.5%+5)
600A
1A
Effectiveness of Button
With the function/range switch in a certain range position, not all the buttons are effective. For different range
positions, the buttons have different effectivenesses. For more detailed information, see the following table.
Button
Range
RANGE
FUNC.
MAX.
H
DATA
H
•
•
•
•
•
•
Ω
•
•
•
•
ºC/ºF
•
•
2/20A
•
•
•
200/600A
•
•
•
OPERATION INTRODUCTION
Measuring Voltage
Connect the black test lead to the „COM” jack, and the red one to the „
1.
” jack,
Set the function/range switch to
2.
or
position.
Connect the test leads to the electrical source or load to be measured.
3.
Read the voltage value on the LCD. The polarity of the red test lead will be indicated along with the voltage
4.
value.