1、Stand Alone Mode  

1.Stand Alone Mode: Auto, manual and sound 

2.Working Mode Setting:Press different button to enter different working mode 

2、Master/ Slave Mode  

1.Master/ Slave Mode: Auto, manual and sound mode and no need to use controller。 

2.Working Mode Setting:Select one unit as the master(auto sound or manual),set up DMX address A001 in 

other units,and all lights light Sequence Par.0 at the same time.   

Master/ Slave Mode

 

 

 

 

 

 

 

 

Dmx line

Power line

Light 

Signal

 

Par Par.0

A001 

Dmx line

Power line

Light 

Signal

 

Par Par.0

A001 

AC Power 

100~240VAC 

50/60Hz 

Power line

Light 

Signal

 

Par Par.0 

Host 

3.Cable Connection in Master/Slave mode:Connect the DMX output of the master and the input of the first 

slave unit with XLR-XLR cables, then connect the output of the first slave unit with the input of the second 

unit, the rest may be deduced by analogy until all the slave units are connected.  

4. Four Channel Control Mode:Set up 4-channel mode for all the Par Lights in the loop. Press Menu Button 

until 4-CH is showed.  

Note: If more than one piece master unit or DMX controller, 4-channel controller is connected, the slave 

units may work out of the way  

 

3、Master and Slave Working Mode for Par Light Set 

1.Working Mode Setting:Set up the DMX address: A001 on all the Slave units and Par Light Sequence Par.1~4  

Four pieces Par lights can form one set. Or the fixture can link with other products Neo-Neon produces so 

as to get more abundant stage effect.   

     

Fixture 1:IRDIP-9007426-00D-13(Single Unit 7x10W(4IN1))

、IRDIP-9028426-00D-13(Light Set 7x10W(4IN1)) 

     Fixture 2:IRDIP-4016126-00D-13(Single Unit 16x3W(RGBW))

、IRDIP-4064126-00D-13(Light Set 16x3W(RGBW)) 

     Fixture 3:IRDIP-2016126-00D-13(Single Unit 16x1W(RGBW))

、IRDIP-2064126-00D-13(Light Set 16x1W(RGBW)) 

     Fixture 4:IRDIP-9028444-00D-11(Double Light 7x10W(4IN1))

(For development ) 

     Fixture 5:IRDIP-4064164-00D-11(双灯 16x3W(RGBW))

(For development) 

     Fixture 6:IRDIP-2016124-00D-11(双灯 16x1W(RGBW))

(For development) 

     Fixture 7:IRDIP-9012426-00D-13(Epar-12x10W(4IN1)Par Light) 

 

Installation  

Hanging Or Level Installation    

Please find the hole in the middle of the bracket and fix the light with the clamp through these holes before 

hanging. You can use hanging cable as assistance. Make sure that the hanging cable can bear the weight which 

is 10 times of the hanging subjects.  

 

 

 

 

5/ 7 

Summary of Contents for IRDIP-9007456-01D-13

Page 1: ...ys long life span It can work in DMX Manual Auto Sound and Linkable modes It is also user friendly which makes it suitable for all kinds of entertainment and decorative industries The fixture can be used as a single unit or a PAR Light Set 4 PCS or 4 N PCS Packing Listing 1 IRDIP 9007456 01D 13 7x10W 4IN1 Indoor Par Light One 2 User Manual One 3 Power Cable One 4 DMX Cable One 1 7 ...

Page 2: ...r charge PAR Light Setting 1 Five Working Modes 1 Auto Run the internal program automatically 2 Manual Run the program manually 3 Sound Run the internal program by sound 4 DMX512 DMX control Mode 5 4 Channels Mode Run under the control by 4 Channels controller 2 Key Pressing and Digital Tube Setting 2 1 Operation Panel as Picture 2 shows MENU UP DOWN ENTER Picture 3 Picture 2 2 2 Instruction on Di...

Page 3: ...each mode 3 3 Manual Mode Under this mode RGB brightness and strobe speed can be set manually r 000 r 008 refers to the brightness of red color g 000 g 008 refers to the brightness of green color b 000 b 008 refers to the brightness of blue color u 000 u 008 refers to the brightness of white color Strobe speed setting is the same as 3 2 3 4 Sound Mode Adjust the sound sensitive to the most suitabl...

Page 4: ...djustment 0 100 CH6 Blue Brightness Adjustment 000 255 Blue Brightness Adjustment 0 100 CH7 White Brightness Adjustment 000 255 White Brightness Adjustment 0 100 四 Instruction on Par Light Set 5 1 Controlled By DMX Controller 5 1 1 Connection AC Power 100 240VAC 50 60Hz DMX512 Controller 4 Channel Controller 5 1 2 Channel Listing Light 1st Par Par 1 Dmx line Light 2nd Par Par 2 Dmx line Power line...

Page 5: ...lection 016 255 Strobe Speed Selection CH4 Red LED Brightness Adjustment 000 255 Par 1 Red LED Brightness 0 100 CH5 Green LED Brightness Adjustment 000 255 Par 1 Green LED Brightness 0 100 CH6 Blue LED Brightness Adjustment 000 255 Par 1 Blue LED Brightness 0 100 CH7 White LED Brightness Adjustment 000 255 Par 1WhiteLED Brightness 0 100 CH8 Red LED Brightness Adjustment 000 255 Par 2 Red LED Brigh...

Page 6: ...iece master unit or DMX controller 4 channel controller is connected the slave units may work out of the way 3 Master and Slave Working Mode for Par Light Set 1 Working Mode Setting Set up the DMX address A001 on all the Slave units and Par Light Sequence Par 1 4 Four pieces Par lights can form one set Or the fixture can link with other products Neo Neon produces so as to get more abundant stage e...

Page 7: ... input voltage 1 Make sure that the input voltage is the same as the rating voltage The unit is not controlled by the DMX 1 Check the polarity of the DMX control signal 2 See whether the unit is working under DMX mode 3 Check whether there are two masters 1 Correct the polarity of the DMX signal 2 Set up DMX working mode 3 Select only one master in the loop Light set don t work rightly 1 Check the...

Reviews: