
Parameter 7: Light Sensor Polling Interval
This Parameter can be set as interval time for light sensor measuring ambient illumination
level.
Size: 2 Byte, Default Value: 180
Setting
Description
60 - 36000
Light Sensor Polling Interval
Parameter 8: Lux Level Function Enable
If this parameter is set to ‘1’, and when Lux level is less than the value defined by parameter
#5, PIR sensor will send a BASIC_SET command frame(i.e. BASIC_SET (value = parameter
3) to an associated device and activate it. If Lux Level is greater than the value defined by
parameter #5, PIR sensor will not send a BASIC_SET command frame.
Size: 1 Byte, Default Value: 0
Setting
Description
0
Disable
1
Enable
Parameter 9: Ambient illumination Lux Level Report
This parameter defines how much Lux must be changed first, then PIR sensor will report to z
wave gateway.
Size: 1 Byte, Default Value: 100
Setting
Description
0 - 255
Lux Level Report
Parameter 10: Ambient Temperature Differential Report
This parameter is configured the value that differential between current measured and
previous report value. If the differential value larger than the settings, device will report this
measured temperature value to nodes associated in lifeline.
Size: 1 Byte, Default Value: 5
Setting
Description
0 - 127
Differential Value in step 0,1°C