Nemtek MERLIN M25 User Manual Download Page 7

 

 

      

MERLIN 

Electric Fence Control Panel 

       

 

         User Manual

 

 
 

 

WHAT THE LIGHTS MEAN: 

 

 

Condition: 

Power 

Light 

On 

Light 

Gate 

Light 

Service 

Light 

Good 

Light 

Fence 

Light 

Remarks 

FENCE GOOD 

ON 

ON 

OFF 

OFF 

SLOW 
FLASH 

OFF 

Fence on, working 
properly 

FENCE OFF 

ON 

OFF 

OFF 

OFF 

OFF 

OFF 

Fence off, working 
properly 

MAINS FAILURE 

OFF 

 

 

 

 

 

System on battery 

power 

BATTERY LOW 

SLOW 
FLASH 

 

 

 

 

 

Check mains supply 

BATTERY FLAT 

SLOW 
FLASH 

SLOW 
FLASH 

 

FAST 

FLASH 

 

 

Check mains, call for 
service 

FENCE CHECK 

 

SLOW 

FLASH 

 

 

OFF 

OFF 

Check fence for 

vegetation 

FENCE CHECK 

 

ON 

 

 

OFF 

OFF 

Check fence for 
vegetation 

FENCE ALARM 

 

 

 

 

OFF  

FAST 

FLASH 

Problem on fence 

FENCE LV MODE 

 

SLOW 

FLASH 

 

 

 

 

Fence in low voltage 

mode 

FENCE BYPASS 

 

 

 

 

 

SLOW 
FLASH 

Fence alarm switched 
off 

GATE OPEN 

 

 

FAST 

FLASH 

 

 

 

Gate is open 

GATE BYPASS 

 

 

SLOW 
FLASH 

 

 

 

Gate alarm is 
switched off 

INSTANT GATE 

 

 

PULSE 

(5 SEC) 

 

 

 

Instant gate alarm 

SERVICE ALARM 

 

 

 

FAST 

FLASH 

 

 

Call for service 

SERVICE BYPASS 

 

 

 

SLOW 
FLASH 

 

 

Service alarm is 
switched off 

ALARM MEMORY 

 

 

(ON) 

(ON) 

 

(ON) 

Old alarm condition 

 

 
 

 

 
 

 
 

 

NEMTEK GROUP OUTLETS 

 
 

RANDBURG 

 

Tel: +27 (0)11 462-8283 
Fax: +27 (0)11 462-7132 

EDENVALE

Tel: +27 (0)11 453-1970

Fax: +27 (0)11 453-1858

Web site:  http//www.nemtek.com 

E-mail:  [email protected] 

 
 

MANUFACTURED IN SOUTH AFRICA  

Summary of Contents for MERLIN M25

Page 1: ...GROUP OF COMPANIES USER MANUAL M28 M25 MERLIN M SERIES Electric Fence Control Panel FENCE GATE SERVICE DUAL ZONE ...

Page 2: ...nd push the key enter the digit 3 then push key The control panel will beep three times to confirm the fence is in low voltage mode When the fence is on and in low voltage mode the red ON light will flash The red ON light will stay lit if the fence is in high voltage mode BYPASS THE FENCE ALARM ZONE 1 2 Enter your PIN and push the key enter the digit 1 then push the key The control panel will beep...

Page 3: ...ARM IMMEDIATE GATE 1 Enter your PIN and push the key followed by the digit 7 followed by the digit 1 then push the key The control panel will beep twice and the GATE ALARM and GATE 1 lights will start flashing very slowly every 5 seconds to confirm that the gate 1 alarm is immediate Enter your PIN and push the key enter the digit 2 followed by the digit 7 followed by the digit 1 then push the key ...

Page 4: ...AYED GATE 2 Enter your PIN and push the key enter the digit 4 followed by the digit 2 then push the key The control panel will beep twice to confirm that the gate 2 alarm is delayed The default delay time is 4 minutes Enter your PIN and push the key enter the digit 2 followed by the digit 4 followed by the digit 2 then push the key The control panel will beep twice to confirm that the gate 2 alarm...

Page 5: ... bypassed To cancel the bypass repeat the same sequence of keys TURN THE GATE CHIME ON OFF GATE 1 2 Push the key then push the key The control panel will beep twice to confirm that the gate chime is turned off and three times if it s turned on If the chime is on the control panel will beep twice if gate 1 or 2 closes and three times if it opens 2 Push the key enter the digit 2 then push the key Th...

Page 6: ... the key The control panel will beep 3 times and the SERVICE ALARM light will start flashing slowly to confirm that the service alarm is bypassed To cancel the bypass repeat the same sequence of keys STANDBY BATTERY TEST 6 Push the key enter the digit 6 then push the key The control panel will beep twice and start testing the battery The default battery test duration is 5 minutes CHANGING A USER P...

Page 7: ... for vegetation FENCE CHECK ON OFF OFF Check fence for vegetation FENCE ALARM OFF FAST FLASH Problem on fence FENCE LV MODE SLOW FLASH Fence in low voltage mode FENCE BYPASS SLOW FLASH Fence alarm switched off GATE OPEN FAST FLASH Gate is open GATE BYPASS SLOW FLASH Gate alarm is switched off INSTANT GATE PULSE 5 SEC Instant gate alarm SERVICE ALARM FAST FLASH Call for service SERVICE BYPASS SLOW ...

Reviews: