BYPASS THE SIREN AND STROBE LIGHT (SILENT ALARM) 

 

 

Enter your PIN and push the * key, enter the digit ‘4’, then push the # key.  The control panel will beep 3 
times to confirm the siren and strobe light is bypassed.  The beeper in the control panel and the 
energizer unit will still be active. 

 

 

UN-BYPASS THE SIREN AND STROBE LIGHT 

 

 

Enter your PIN and push the * key, enter the digit ‘7’, then push the # key.  The control panel will beep 
twice to confirm that the siren and strobe light is NOT bypassed. 

 

 

MAKE THE GATE A LARM IMMEDIATE (GATE 1 & 2) 
 

 

Enter your PIN and push the           key, followed by the digit ‘7’, then push the # key.  The control panel 
will beep twice and the GATE ALARM and GATE 1 & 2 lights will start flashing very slowly (every 5 
seconds) to confirm that the gate 1 & 2 alarms are immediate. 
 

 

 

 

Enter your PIN and push the * key, enter the digit ‘2’ followed by the digit ‘7’, then push the # key.  The 
control panel will beep twice and the GATE ALARM and GATE 1 & 2 lights will start flashing very slowly 
(every 5 seconds) to confirm that the gate 1 & 2 alarms are immediate. 

 

 

MAKE THE GATE ALARM IMMEDIATE (GATE 1) 
 

 

Enter your PIN and push the           key, followed by the digit ‘7’, followed by the digit ‘1’, then push the 
# key.  The control  panel will beep twice and the GATE ALARM and GATE 1 lights will start flashing very 
slowly (every 5 seconds) to confirm that the gate 1 alarm is immediate. 

 
 

 

 

Enter your PIN and push the * key, enter the digit ‘2’ followed by the digit ‘7’, followed by the digit ‘1’, 
then push the # key.  The control panel will beep twice and the GATE ALARM and GATE 1 lights will start 
flashing very slowly (every 5 seconds) to confirm that the gate 1 alarm is immediate. 

 

 

MAKE THE GATE ALARM IMMEDIATE (GATE 2) 

 
 

Enter your PIN and push the           key, followed by the digit ‘7’, followed by the digit ‘2’, then push the 
# key.  The control panel will beep twice and the GATE ALARM and GATE 2 lights will start flashing very 
slowly (every 5 seconds) to confirm that the gate 2 alarm is immediate.

 

 
 
 

 

Enter your PIN and push the * key, enter the digit ‘2’ followed by the digit ‘7’, followed by the digit ‘2’, 
then push the # key.  The control panel will beep twice and the GATE ALARM and GATE 2 lights will start 
flashing very slowly (every 5 seconds) to confirm that the gate 2 alarm is immediate. 

#

4

#

7

#

7

2

OLD 

VERSION 
KEYPAD 

NEW 

VERSION 
KEYPAD 

OLD 

VERSION 
KEYPAD 

NEW 

VERSION 

KEYPAD 

OLD 

VERSION 
KEYPAD 

NEW 
VERSION 

KEYPAD 

#

7

1

 

#

 

7

 

#

 

7

 

1

 

2

 

2

 

#

 

7

 

#

 

7

 

2

 

2

 

Summary of Contents for MERLIN M25

Page 1: ...GROUP OF COMPANIES USER MANUAL M28 M25 MERLIN M SERIES Electric Fence Control Panel FENCE GATE SERVICE DUAL ZONE ...

Page 2: ...nd push the key enter the digit 3 then push key The control panel will beep three times to confirm the fence is in low voltage mode When the fence is on and in low voltage mode the red ON light will flash The red ON light will stay lit if the fence is in high voltage mode BYPASS THE FENCE ALARM ZONE 1 2 Enter your PIN and push the key enter the digit 1 then push the key The control panel will beep...

Page 3: ...ARM IMMEDIATE GATE 1 Enter your PIN and push the key followed by the digit 7 followed by the digit 1 then push the key The control panel will beep twice and the GATE ALARM and GATE 1 lights will start flashing very slowly every 5 seconds to confirm that the gate 1 alarm is immediate Enter your PIN and push the key enter the digit 2 followed by the digit 7 followed by the digit 1 then push the key ...

Page 4: ...AYED GATE 2 Enter your PIN and push the key enter the digit 4 followed by the digit 2 then push the key The control panel will beep twice to confirm that the gate 2 alarm is delayed The default delay time is 4 minutes Enter your PIN and push the key enter the digit 2 followed by the digit 4 followed by the digit 2 then push the key The control panel will beep twice to confirm that the gate 2 alarm...

Page 5: ... bypassed To cancel the bypass repeat the same sequence of keys TURN THE GATE CHIME ON OFF GATE 1 2 Push the key then push the key The control panel will beep twice to confirm that the gate chime is turned off and three times if it s turned on If the chime is on the control panel will beep twice if gate 1 or 2 closes and three times if it opens 2 Push the key enter the digit 2 then push the key Th...

Page 6: ... the key The control panel will beep 3 times and the SERVICE ALARM light will start flashing slowly to confirm that the service alarm is bypassed To cancel the bypass repeat the same sequence of keys STANDBY BATTERY TEST 6 Push the key enter the digit 6 then push the key The control panel will beep twice and start testing the battery The default battery test duration is 5 minutes CHANGING A USER P...

Page 7: ... for vegetation FENCE CHECK ON OFF OFF Check fence for vegetation FENCE ALARM OFF FAST FLASH Problem on fence FENCE LV MODE SLOW FLASH Fence in low voltage mode FENCE BYPASS SLOW FLASH Fence alarm switched off GATE OPEN FAST FLASH Gate is open GATE BYPASS SLOW FLASH Gate alarm is switched off INSTANT GATE PULSE 5 SEC Instant gate alarm SERVICE ALARM FAST FLASH Call for service SERVICE BYPASS SLOW ...