16
Energizer Operation
Amber:
The display will go amber when
the energizer is on but it is taking action to
keep the energizer operating correctly. The
display will show the same parameters as on
the green display.
-
When the energizer effort is either
below or above set levels the display
will go amber
-
If the energizer internal temperature is
high the energizer will start operating in
a reduced energy mode to prevent over
heating and the display will go amber
and will show a thermometer symbol
Red:
The display will go red and the
energizer will switch off when the input
supply voltage drops too low for the
energizer to operate. The display will show
the word “bAtt” and in small characters the
supply voltage.
-
If a service condition is detected the
energizer will switch off and the display
will go red, it will also show a picture of
a spanner
-
When a heavy fence load has dropped
the output voltage at the HT terminals
below the set low fence voltage alarm
level, the energizer will keep on
operating but the display will go red and
show the same parameters as shown on
the green display
-
If the internal temperature of the
energizer goes over a set level the
energizer will drop its output to a
very low energy level, the display
will go red and show the symbol
for a thermometer
-
When the fence condition changes
to an extent that potentially there
could be an animal/human stuck in
the fence, the energizer will alarm
and the display will go red and
show the warning triangle. The
energizer will still operate but the
time between impulses will be
longer
-
If a sudden decrease in fence load
is detected excess energy will be
diverted from the fence and the
display will go amber and will
show a triangle with an
exclamation mark