Page 1: ...AGRI 80 150 and 200 Electric Fence Energizers Instruction Manual...

Page 2: ...ns 7 Product Specifications 8 Product Identification and Energizer Description 9 Mounting the Energizer 10 Installation Instructions 11 Fence Wiring 12 Energizer Operation 15 Installation Notes 17 App...

Page 3: ...ntrapment hazards See APPENDIX at the end of this manual and warn the user to avoid head contact with the fence DISCLAIMER Nemtek Holdings Pty Ltd or any of its subsidiary companies does not guarantee...

Page 4: ...emtek Group outlets The buyer shall pay all shipping and other charges for the return of the product to Nemtek or Nemtek Security Warehouse LIMITATION OF GUARANTEE The guarantee does not apply to defe...

Page 5: ...3 752 2187 Waterval Ave Riverside Industrial Fax 27 0 13 752 2188 Nelspruit South Africa KWAZULU NATAL Email manager kzn nemtek co za Tel 27 0 31 701 2125 19 Henwood Road Fax 27 0 31 701 3728 Pinetown...

Page 6: ...e delayed electric fence energizer and when it detects a very low impedance at the output terminals it will limit the energy of its output pulses for a delay time of 15 seconds but permits the output...

Page 7: ...energizers are not security energizers but designed for livestock and game control Switch the energizer off before working on the fence Do not open the energizer there are no removable fuses or servic...

Page 8: ...8kV 9 7kV Environmental Rating IP65 IP65 IP65 Fence Wire Length Ideal Condition 80km 150km 200km Fence Wire Length Average Condition 24km 42km 56km Guideline PV Panel location dependent 80W 160W 240W...

Page 9: ...l The Fence terminals are on the font of the energizer with the green earth terminal on the left and the red high voltage output terminal on the right which normally connects via the lightning diverte...

Page 10: ...d wall Position the casing so that the screws go through the slots provided then drop it into position If necessary tighten the top 2 screws slightly more to secure the casing The bottom two screws wi...

Page 11: ...ghtning diverter together with the energizer If vented rechargeable batteries are used to supply the energizer ensure that they are placed in a well ventilated area Non rechargeable batteries should n...

Page 12: ...the thickness of their coats or hides Sheep goats and wild animals generally require higher voltage levels compared to horses pigs and cows EARTHING THE FENCE The earthing component of the fence is ve...

Page 13: ...poor soil conditions or seasonal changes in the soil moisture levels you will require additional earthing You will need one or more earth wires along your fence in addition to your live wires Earth s...

Page 14: ...or livestock will require higher tensile strengths be more robust have a longer life span and use more durable insulators and equipment Animals tend to run into the fence before seeing it and they co...

Page 15: ...upply voltage to the energizer is displayed in the top right corner Green The energizer is on and the LCD displays shows the following In large characters the output fence voltage in kilovolts kV meas...

Page 16: ...switch off and the display will go red it will also show a picture of a spanner When a heavy fence load has dropped the output voltage at the HT terminals below the set low fence voltage alarm level...

Page 17: ...s use ferrules or line clamps to connect two high voltage wires together Avoid using dissimilar materials for connections like copper on steel The fence must be earthed properly with three earth spike...

Page 18: ...ic fence used to contain animals within or exclude animals from a particular area Public Access Area Any area where persons are protected from inadvertent contact with pulsed conductors by a physical...

Page 19: ...s are used or sleeving rated at 10kV Barbed wire or razor wire shall not be electrified by an energizer or placed physically close to an electric fence as these circumstances can create a lethal entan...

Page 20: ...emergency services Gates in electric animal fences shall be capable of being opened without the person receiving an electric shock Connecting leads that are run inside buildings shall be effectively i...

Page 21: ...e wires are installed near an overhead power line their height above the ground shall not exceed 3m If connecting leads and electric fence wires are installed near an overhead power line their height...

Page 22: ...knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Electric fencing can be lethal Avoid head contact with the fen...