Nemox i-Geen z4 MAGIC PRO 100 Instruction Book Download Page 10

10

English

DEFROST: 

IMPORTANT: the appliance has manual defrosting. 

When the formation of ice on the walls of the tank exceeds the thickness of 0.5cm, it is necessary to defrost in order 

not to compromise the thermal efficiency of the storage.

Proceed as follows: 

•  Remove the plug from the socket. 

•  Transfer the product stored in the trays to another suitable storage device. 

•  Place the container (10) under the collector (9) located under the storage case. 

• 

Remove the drain plug (9) and let the internal ice melt and the water flow from the drain (9). Dry thoroughly.

•  When the tank is completely dry, put the plug into the socket. 

•  Wait for the appliance to reach operating temperature before placing trays with gelato. 

•  Never use a metal or sharp tool to remove ice.

EFFICIENCY

To maintain the device efficiency operation, clean the condenser regularly. This operation falls outside normal mainte

-

nance and should be performed by a qualified technician, who should proceed as follows:

•  Switch off the machine by the switch (1) and remove the plug from the electrical socket.

• 

Clean the condenser with a brush, air jet or suction device to avoid damaging the device.

•  Restart the storage unit.

POSSIBLE PROBLEMS

The countertop is not running, programmer is not light up.

• 

The plug (12) has not been connected to power supply socket (11).

•  Back button is switched off.

The storage is not working, programmer is light up.

•  The control system waits 5 minutes before restarting the compressor

•  The storage was turned off and an attempt was made to restart it immediately.

Compressor stay always switched on, or it switch on and off frequently.

• 

The room temperature is above 30 ° C. 

• 

Excessive quantity of gelato has been placed in the storage and the mass is not yet at the correct temperature. 

•  The ventilation grilles (14) are blocked 

Vibrations. 

•  Check that the storage is in a horizontal position. 

The storage case makes too much noise. 

• 

The noise may come from the flow of refrigerant gas, this is normal. 

• 

The contraction and expansion of the internal walls can cause creaking. 

•  The storage is not in level position. 

The electronic programmer is not working properly. 

•  If an error message other than those described in this manual appears on the display, contact an authorized Service 

Center. 

Summary of Contents for i-Geen z4 MAGIC PRO 100

Page 1: ...www nemox com 4 MAGIC PRO 100 EN INSTRUCTION BOOK...

Page 2: ...2 English x4 9 9 4 magic pro 100 14 12 11 1 5 4 2 8 10 3 7 6 13...

Page 3: ...ng of your machine Should you need to return it for any reason please provide to pack it preferably in its original packaging If the machine is delivered in a packaging that is not suitable for shipme...

Page 4: ...d is damaged it must be replaced by the manufacturer its service agent or similar qualified persons in order to avoid a hazard Unplug from outlet when not in use before putting on or taking off parts...

Page 5: ...es hotplates or near open gas flames Do not put any part in the dishwasher Do not unplug the unit by pulling on the cord The appliance must be connected to an electrical system and power supply socket...

Page 6: ...ntains a small quantity of R290 refrigerant gas which is flammable The refrigerant quantity contained in this appliance is marked on the rating plate of the appliance Do not allow any sharp objects to...

Page 7: ...ts For this purpose the electrical and electronic equipment producers and distributors set up proper collection and treatment systems for these products At the end of life your product contact your di...

Page 8: ...with the letter E or the Earth symbol G or coloured Green or Green and Yellow The wire that is coloured Brown must be connected to the terminal which is marked with the letter L or coloured Red The wi...

Page 9: ...troducing the product The compressor will turn on again when the temperature measured in the tank differs by 2 C more than the set one By pressing the on off button 7 for 2 seconds the storage can be...

Page 10: ...e plug from the electrical socket Clean the condenser with a brush air jet or suction device to avoid damaging the device Restart the storage unit POSSIBLE PROBLEMS The countertop is not running progr...

Page 11: ...17 6 33 27 4 16 60 8 9 15 8 34 29 2 15 59 10 14 35 31 14 57 2 11 12 2 36 32 8 13 55 4 12 10 4 37 34 6 12 53 6 13 8 6 38 36 4 11 51 8 14 6 8 39 38 2 10 50 15 5 40 40 9 48 2 16 3 2 41 41 8 8 46 4 17 1 4...

Page 12: ...NEMOX International S r l Via E Mattei N 14 25026 Pontevico Brescia ITALY www nemox com CERTIFIED ISO 9001 2015 COD EN506916...

Reviews: