![Nemox gelatissimo exclusive i-green User Instructions Download Page 8](http://html.mh-extra.com/html/nemox/gelatissimo-exclusive-i-green/gelatissimo-exclusive-i-green_user-instructions_718557008.webp)
A successful recipe is a mixture of
top quality ingredients and excellent
machine efficiency.
Wash the blades (B) and (F), the
transparent cover (D), the fixing knob
(C), the spatula (E), the ring (O) and the
removable bowl (G) with hot water and
soap.
These parts can also be cleaned
in the dishwasher
on a low temperature
cycle.
Making a good, healthy and natural
ice cream or sorbet, with the right
consistency, depends on various
factors; here are a few suggestions:
WHAT DO YOU NEED TO MAKE A
GOOD ICE CREAM OR SORBET?
Good, fresh and well balanced
ingredients must be used.
Make sure the machine is turned off
(check the main power switch) and
unplugged before carrying out any
cleaning.
Another ice cream can be prepared after
a brief standby time (approx. 10
minutes), by repeating the steps
described.
An appliance that is in good working
order: leave enough space on the
counter to allow air to circulate freely.
Air is needed to cool the compressor.
After use, turn off the switch (S) and
disconnect the machine from the mains.
CLEANING THE MACHINE
Serve the preparation in pre-cooled
containers.
Lift it up and
CHECK THAT THE
E X T E R N A L W A L L O F T H E
REMOVABLE BOWL IS ALL WET
,
otherwise the machine will not cool
properly.
Insert the mixing blade for a removable
bowl (F)
Tighten the fixing knob (C).
ATTENTION!:
The machine is ready for use
When the ice cream reaches the
intended consistency, stop the machine
by pressing all the buttons and remove
the ice cream.
Place the transparent cover (D).
Press the switch (M) to start the mixing
blade.
When you have used the fixed bowl and
want to extract the ice cream, remove as
much as possible with the spatula (E) or
a plastic or wooden utensil. Remove the
ring (O) and then the blade (B). Reinsert
the ring (O) before removing the ice
cream left in the bowl. This step prevents
the ice cream or other ingredients from
infiltrating under the seal and therefore,
into the machine.
when using a saline solution, once you
have finished using the machine,
thoroughly wash and dry
both the fixed
and removable bowls
to prevent
corrosion
. Do not leave the saline
solution inside the bowl!
M A K I N G I C E C R E A M W I T H
GELATISSIMO EXCLUSIVE I-GREEN
How to proceed:
Ensure that the voltage indicated on the
data plate matches the mains voltage.
Insert the power plug into the socket.
Press the main switch (N) and then the
switch (L) to start the cooling cycle. Pre-
cool the bowl for 5 minutes.
Pour the mixture.
English
9
8
IMPORTANT:
This machine contains a refrigerant that
must be allowed to settle after being
transported.
Leave the machine
on a
flat surface for
at least 12 hours
after
purchasing it or after any movement,
during which the machine has been
turned over. Leave at least 20 cm on
each side of the machine to allow free air
circulation. Make sure the ventilation
slots are free and unobstructed. A flow of
hot air that escapes from the vents is the
normal result of efficient refrigeration.
•Variations in speed and noise when
preparing ice cream are normal and do
not affect proper machine operation.
B) Use with a removable bowl
A) Use with a fixed bowl
•The machine has a recommended 800
g capacity. If more ingredients are
added, the volume will increase during
the production process and the
preparation may leak. Furthermore, the
consistency may be less compact.
Pour 1 or 2 measuring cups (H) of a salt
and water solution (20 g salt and 80 g
water) into the fixed bowl or of a spirit
with an ABV higher than 40° or of food-
grade alcohol.
Insert the protection ring (O).
P R E L I M I N A R Y W A R N I N G S T O
F O L LO W B E F O R E U S I N G T H E
MACHINE
•
Do not fill the bowl by more than half.
The volume increases during the
freezing process and may reach the
maximum volume capacity of the bowl.
•Hygiene is extremely important when
processing food. Make sure that all
parts, in particular those coming in direct
c o n t a c t w i t h t h e i c e c r e a m , a r e
thoroughly cleaned.
•After having stopped the machine, wait
about 10 minutes before turning it on
again.
Fully insert the removable bowl (G) into
the fixed bowl and press firmly.
•Do not turn off the refrigeration system
(L button) or the main switch (N) when
the machine is working. Wait about 10
minutes before restarting it in the case of
an incorrect operation or an accidental
power disconnection. The compressor
is fitted with a safety device that prevents
damage. The refrigeration system will
not work for three minutes if the machine
is restarted immediately.
•Pour the ingredients into a separate
container and mix.
Insert the mixing blade for a fixed bowl
(B)
Tighten the fixing knob (C).
OPTIONS OF USE
•Use pre-cooled ingredients. It is
advisable to introduce the ingredients
i n t o t h e i c e c r e a m m a k e r a t a
temperature b5°C and +20°C,
o t h e r w i s e t h e r e s u l t c o u l d b e
compromised.
The machine is ready for use
This machine is supplied complete with
all accessories to be used with a fixed
bowl and a removable bowl. The
removable bowl is inserted inside the
fixed bowl in the original packaging.
English