background image

 

 

 

PERFORMANCE INSURANCE

 

PRODUCTION TOOLS    

    SHOW CONTROL    

    BACKUP SOLUTIONS

 

www.nemesis-research.com

 

OSC Listen Port 

53500 

 

In order to change settings navigate to the device's IP address (default: 192.168.1.253) on the 

network using a web browser or use its network name (default: OSCA-I8) and navigate to the 

“Network page”  

In order for changes to take effect press save and then restart (Please note if you have changed 

IP address or device name the page may not refresh, and you will need to open a new tab in your 

browser with the new user settings).  

Destination Settings 

On the Destinations page, you can specify and name destinations (a maximum of 8 when in 

advanced mode and 2 when in a preset) which will be stored in the device's memory. Please 

specify the IP address and OSC listen to port of the receiving device(s). 

Input Settings 

Each input can send up to two messages (Command), with each one sent to one of eight 

destinations. (to send the same command to both destinations send identical command to each 

location) 

The device comes with three pre-sets built-in with predefined commands for CSC and Qlab and 

OSCA-O4. 

 

All commands in these pre-sets will be sent to Destination 1 and 2 (if specified on the 

destinations page) 

Qlab Preset 

Button 

Function 

Command 

Go 

/go 

Stop 

/panic 

Previous 

/playhead/previous 

Next 

/playhead/next 

Not used 

 

 

When using this pre-set it may be necessary to configure QLab to allow OSC connection access 

without a passcode. 

 

CSC Preset 

Button 

Function 

Message (Command) 

Go 

/cuelist/go 

Stop 

/cuelist/stop 

Previous 

/cuelist/prev 

Next 

/cuelist/next 

Not used 

 

 

OSCA-O4 Preset 

Button 

Function 

Address 

Integer Argument  

Relay 1 ON 

/relay/1  

Relay 2 ON 

/relay/2 

Relay 3 ON 

/relay/3 