Part 2 Technical Manual Of Motherboard
29
Console Redirection Settings
The settings specify how the host computer and the remote computer
(which the user is using) will exchange data. Both computers should have
the same or compatible settings.
Press [Enter] to make settings for the following sub-items.
Out-of-Band Mgmt Port
The default setting is: [COM1].
Terminal Type
The optional settings are: [VT100]; [VT100+]; [VT-UTF8]; [ANSI].
Bits per second
The optional settings are: [9600]; [19200]; [57600]; [115200].
Flow Control
The optional settings are: [None]; [Hardware RTS/CTS]; [Software
Xon/Xoff].
Data Bits
The default setting is: [8].
*This item may or may not show up, depending on different
configuration.
Parity
The default setting is: [None].
*This item may or may not show up, depending on different
configuration.
Stop Bits
The default setting is: [1].
*This item may or may not show up, depending on different
configuration.
PC Health Status
Press [Enter] to view current hardware health status, set shutdown
temperature, or make further settings in ‘
Smart Fan Configuration
’.
SmartFAN Configuration
Press [Enter] to make settings for SmartFAN Configuration:
CPUFAN / SYSFAN Smart Mode
The optional settings: [Disabled]; [Enabled].
When set as [Enabled], the following sub-items shall appear:
CPUFAN / SYSFAN Full-Speed Temperature
Use this item to set CPUFAN/SYSFAN1/ SYSFAN2 full speed
temperature. Fan will run at full speed when above the preset
temperature.
CPUFAN / SYSFAN Full-Speed Duty