background image

APPLICATION

AR luminaires are designed for use indoors, outdoors, wet locations, and areas containing moisture, 

dirt, corrosion, vibration, and rough usage. NSF Models (ARxx-xxx-xx-xx-FS-XX) of the luminaire is 

certified by NSF for use in Splash-zone and Non-Food areas of food processing locations as defined in 

NSF-2. The AR luminaire is also certified for use on marine vessels inside, outside and in other severely 

wet saltwater environments. Models ARXX-XXX-XX-XX-HZ-XX are certified for use in hazardous location 

areas.

UL File Numbers:                    Nemalux General Location: E477827

 

 

 

        Nemalux Hazardous Location: E477829

AR luminaires are suitable for use in the following areas as defined by the National Electrical Code 

(NEC) and the Canadian Electrical Code (CEC):

Certifications all models:      UL 1598, UL 1598A and UL 8750; 

 

 

 

        CSA C22.2 No. 250.0 and CSA C22.2 No. 250.13 

 

 

 

        ABS Listed

Certifications Hazardous Location models (ARXX-XXX-XX-XX-HZ-XX)

 

 

 

        UL 844, CSA C22.2 No. 137

 

 

 

        Hazardous Location Approved Locations: 

 

 

 

        Class I, Division 2, Groups ABCD, T4; 

 

 

 

        Class II, Division 2, Groups FG, T4A; 

 

 

 

        Class III;

 

 

 

        Class I, Zone 2, Group IIC;

 

 

 

        Zone 22

Certifications NSF models (ARXX-XXX-XX-XX-FS-XX)

 

 

 

        NSF/ANSI 2 Splash and Non-Food Zone

Housing:  

 

          Copper-free Cast Aluminum with Polycarbonate lens

Input Voltage:   

          Based on luminaire suffix in table below: Suffix - AC: 120-277 VAC | Suffix - HV: 347-480 

VAC  

 

Inrush Current:                    AR (AC): Inrush Current Peak / >50% Duration 120V: 62A / 210uS  277V: 148A / 200uS

                                                  AR (HV): Inrush Current 347V: 118.4A / 97uS Peak / >50% Duration 480V: 148A / 79uS

Connections:   

          2 x 3/4” NPT Conduit | Black: Line | White: Neutral/Line 2 | Green: Ground

 

 

 

          

Optional:   Violet (Purple): 0-10V Dimming (+)  |  Grey: 0-10V Dimming (-)

  

 

 

          For connections use wire rated to a minimum of 90°C.  Class 1 Wiring only.

 

 

 

          Dimming control wires must be rated 300V minimum for luminaires with suffix AC, 

 

 

 

          600V minimum for luminaires with suffix HV.

Ingress Protection: 

           IP66/67  | Suitable For Wet Locations. Marine Outside Type (Salt Water)

TM

Nemalux

I N D U S T R I A L

AR Series

rev. A-30

1-16

www.nemalux.com  |   [email protected]  |   Tel 403•242•7475  |   Fax 403•243•6190 

MADE IN CANADA

Installation

Spec Sheet

Webpage

The AR Series Installation Manual

*White fixture only

Summary of Contents for AR Series

Page 1: ...proved Locations Class I Division 2 Groups ABCD T4 Class II Division 2 Groups FG T4A Class III Class I Zone 2 Group IIC Zone 22 Certifications NSF models ARXX XXX XX XX FS XX NSF ANSI 2 Splash and Non...

Page 2: ...0 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 LUMINANCE AR10 AR15 AR20 AR25 AR30 AMBIENT TEMP C INPUT VOLTAGE AC HV AC HV Optical AC Flood HV Flood 40 to 55 40 to 50 40 to 45 40 to 40...

Page 3: ...hors to the 12 7mm 0 5 holes Suspension hardware Not provided must be rated for a minimum of 180 lbs STEP 4 Open AR Lens with a 7mm socket or wrench and allow Lens to hang via retention strap Note Scr...

Page 4: ...ontrol needs 0 10V Controller must sink current from LED driver 0 10V control connections Dimming controls must be certified and suitable for the classification of the area of their installation NOTE...

Page 5: ...a petrolatum or soap thickened mineral oil based thread lubricant sealant is necessary Un used conduit opening must be plugged to maintain the integrity of the enclosure STEP 5 Insert and tension M6...

Page 6: ...M6 bolts and washers and adhesive backed gasket Apply gasket to mount with adhesive backed side Torque to 5 Nm 45 in lbs STEP 5 Install Back Cover Plate with 4x M4 Flat head screws and adhesive backe...

Page 7: ...sed thread lubricant sealant is necessary Un used conduit opening must be plugged to maintain the integrity of the enclosure STEP 3 Loosely assemble Yoke mount with carriage bolts on inside and washer...

Page 8: ...all hook assembly into NPT threaded entry Tighten to hand tight plus 1 to 2 turns Slide anti rotation lock into place and tighten set screw to lock unit in place NOTE To aid in assembly and protection...

Page 9: ...stem must be rated for 180 lbs NOTE To aid in assembly and protection against ingress use of a petrolatum or soap thickened mineral oil based thread lubricant sealant is necessary Un used conduit open...

Page 10: ...embly and protection against ingress use of a petrolatum or soap thickened mineral oil based thread lubricant sealant is necessary Un used conduit opening must be plugged to maintain the integrity of...

Page 11: ...stall and prevent loss of fasteners STEP 3 Install provided double sided tape along side of surge protector Remove backing paper and place between mounting points as shown with tape side down Install...

Page 12: ...ector to splice or terminal connected to Black leads from LED Drivers 3 Connect White lead from surge protector to splice or terminal connected to Neutral Input branch circuit conductor and White lead...

Page 13: ...nd ensure surge protector is held tightly in place STEP 4 Wire according to wiring instructions on Page 2 Refer to NEC CEC codes and follow all applicable local standards STEP 5 Close AR lens Ensure t...

Page 14: ...LED Drivers 3 Disconnect Neutral Input branch circuit conductor from splice or terminal connected to White leads from LED Driver Re connect Neutral Input branch circuit conductorto Yellow wire from su...

Page 15: ...G ATTENTION INSTALLATION STEPS AR SFY SLIP FITTER YOKE MOUNT Ordered Separately This AR SFY kit is intended for use with UL Listed AR luminaire as marked on the luminaire nameplate Accessory Package C...

Page 16: ...hain to fixed eye bolt not supplied using the second stainless steel oval shaped threaded connecting link Alternate attachment method Wrap loose end of chain around fixed beam or other immovable suppo...

Reviews: