NCD+ 3200 Manual | Control and Display Elements
Part No. 729-110-037 Rev. 1.31 | May 2016
© 2014 Nelson Stud Welding, Inc. All Rights Reserved.
2.3
Process Monitor (PM)
NOTE: Once the unit is powered up, press the knob once to enter the Process Monitor screen.
The Process Monitor uses a series of
“teaching welds" as a target to check each production weld and
to determine if the characteristics of a production weld fall within the natural scatter of teaching welds
(“pass”).
1. Select
Teach
as shown in
Item 1
of
Figure 2.4
.
2. Before entering Teach mode, the target must be cleared.
Select
Yes
(
Item 2
) to confirm that you want to clear any
existing target before proceeding.
3. Turn the dial to desired selection and click.
4. Perform welds (ex. 8-10).
PM in progress with 5 welds
recorded
.
5. Click
Done
(
Item 3
) once finished.
6. Verify results with
Pass/Fail Production
view (
Item 4
).
Figure 2.4 Process Monitor
1
2
3
4