NCD+ 3200 Manual | Control and Display Elements
Part No. 729-110-037 Rev. 1.31 | May 2016
© 2014 Nelson Stud Welding, Inc. All Rights Reserved.
2.2
Stud Expert
NOTE: Once the unit is powered up, press the knob once to enter the Process Monitor screen.
NOTE: To access the Setup screen, return to the Voltage Selection screen (the home screen).
From the Voltage Selection screen, press and hold the knob for 5 seconds to enter the Setup
screen. To exit Setup at anytime and return to the Voltage Selection screen, press and hold the
knob again for 5 seconds.
The Stud Expert mode allows the user to choose welding parameters based on the desired stud size,
stud material and welding process. The resulting cap voltage is set once the stud is selected.
One parameter (stud size, stud material, welding process) can be selected, or all 3, depending on what
are the job requirements.
Turn the knob to scroll through the choices. Once the desired choice is highlighted, push the knob to
select and confirm the choice. The
1. Select the desired stud size (
1/4in (M6)
) as shown in
Item 1
of
Figure 2.3
.
2. Choose from available studs materials, such as Carbon
Steel, as seen in
Item 2
.
3. Choose your desired welding mode; view the resulting cap
voltage; or exit the screen as exemplified in
Item 3
.
Figure 2.3 Stud Expert
3
2
1
Resulting Cap Voltage
Exit the Screen