N1500i FACS Manual
13
Part No. 729-110-053 V.1.03
© 2018 Nelson Stud Welding, Inc. All rights reserved.
1.5 Additional Cautions
SELECT SUITABLE LOCATION
The N1500i will operate in harsh environments. Even so, it is important
that simple preventative measures are followed in order to assure long
life and reliable operation.
The machine must be located where there is free circulation of clean air
such that air movement in the back, out the sides and bottom will not
be restricted.
Dirt and dust that can be drawn into the machine should be kept to a
minimum. Failure to observe these precautions can result in excessive
operating temperatures and nuisance shutdown.
Keep machine dry. Shelter the unit from rain and snow. Do not place
on wet ground or in puddles.
STACKING
•
N1500i cannot be stacked.
TILTING
•
Place the machine directly on a secure, level surface or on a
recommended undercarriage. The machine may topple over if
this procedure is not followed.
INPUT AND GROUNDING CONNECTIONS
•
Only a qualified electrician should connect the N1500i.
Installation should be made in accordance with the appropriate
National Electrical Code, all local codes and info detailed below.
•
When received directly from the factory, 230/460V machines are
internally connected for 460VAC. 575V machines are internally
connected for 575V from the factory.
•
Open the access panel on the rear of the machine.
POWER CORD CONNECTION
•
A power cord is provided and wired into the machine. Follow
the power cord connection instructions.
Caution!
thick, which shall extend not less than 150mm (5.9 inches) beyond the