11

Filte

r

B

r

ass Sh

u

t-off Valve

Coppe

r

 T

u

be

I

n

st

ru

ctio

n

s Fo

r

 Replaci

n

g Pl

um

bi

n

g Pa

r

ts I

n

cl

u

di

n

g Co

n

t

r

ol Valve & Filte

r

Tools Needed:

• 

Safety glasses

• 

(1)

n

eedle-

n

ose plie

r

s - 

m

edi

um

 to s

m

all size.

• 

(1) ope

n

 e

n

d o

r

 adj

u

stable w

r

e

n

ch - 11/16”

• 

(1) ope

n

 e

n

d w

r

e

n

ch - 3/4”

• 

(1) ope

n

 o

r

 boxed e

n

d w

r

e

n

ch - 7/8” 

• 

(1) ope

n

 o

r

 boxed e

n

d w

r

e

n

ch - 7/16”

• 

(1) st

r

aight bit sc

r

ew d

r

ive

r

 - 1/4” 

Re

m

ovi

n

g Filte

r

 a

n

d Co

n

t

r

ol Valve

1

. U

n

latch a

n

d

r

e

m

ove top cove

r

 casti

n

g.

2

. Lock the bala

n

ce bea

m

 off the valve 

u

si

n

g

the bea

m

 lock leve

r

.  This p

r

eve

n

ts the valve

f

r

o

m

 ope

n

i

n

g a

n

d wate

r

 po

ur

i

n

g f

r

o

m

 wate

r

spo

u

t t

u

be.

3

. Re

m

ove d

r

i

n

ki

n

g bowl.

4

. Sh

u

t-off wate

r

 s

u

pply at the b

r

ass sh

u

t-off

valve. (If b

r

ass sh

u

t-off valve is ha

r

d to

access, it 

m

ay be easie

r

 to co

m

e back to

steps 5 a

n

d 6 afte

r

 co

m

pleti

n

g steps 7-9.)

5

. Usi

n

g a 3/4” ope

n

 e

n

d w

r

e

n

ch,

un

faste

n

 the

fla

r

e

nu

t co

nn

ected to the sh

u

t-off valve.  A

seco

n

d w

r

e

n

ch (11/16” ope

n

 o

r

 adj

u

stable)

m

ay be 

n

eeded to hold the b

r

ass sh

u

t-off valve

i

n

 place while 

un

faste

n

i

n

g the b

r

ass fla

r

e

nu

t.

6

. Usi

n

g

n

eedle

n

ose plie

r

s

r

e

m

ove

n

ylo

n

 wate

r

filte

r

 located j

u

st i

n

side the wate

r

 s

u

pply

t

u

be.  Set the filte

r

 aside fo

r

 clea

n

i

n

g.

7

. Usi

n

g 7/16” w

r

e

n

ch

r

e

m

ove the lead co

un

te

r

weight a

n

d set aside.

8

. Usi

n

g

n

eedle

n

ose plie

r

s

r

e

m

ove the cotte

r

pi

n

 o

n

 the tape

r

ed e

n

d of the b

r

ass pivot

shaft a

n

d slide the pivot shaft o

u

t.

9

. The pivot bea

m

 a

n

d cage 

m

ay the

n

 be

r

e

m

oved as a 

un

it. With the pivot bea

m

 a

n

d

cage

r

e

m

oved, it is a good oppo

r

t

un

ity to

clea

n un

de

r

 the c

r

oss bea

m

 a

n

d heate

r

 if

deb

r

is is p

r

ese

n

t. Mice have bee

n

 k

n

ow

n

 to

b

u

ild

n

ests i

n

 this a

r

ea. A wet/d

r

y shop

vac

uum

 wo

r

ks well.

10

. Disco

nn

ect wate

r

 spo

u

t t

u

be f

r

o

m

 plastic locato

r

.

11

. Usi

n

g a 7/8” ope

n

 o

r

 box e

n

d w

r

e

n

ch,

r

e

m

ove b

r

ass hex 

nu

t sec

ur

es the co

n

t

r

ol

valve to the b

r

acket.  Pl

um

bi

n

g sho

u

ld lift o

u

t.

12

. Usi

n

g ha

n

ds,

un

sc

r

ew wate

r

 s

u

pply hose

a

n

d wate

r

 spo

u

t t

u

be f

r

o

m

 each e

n

d of the

co

n

t

r

ol valve.

13

. Whe

n

 i

n

stalli

n

g

n

ew co

n

t

r

ol valve, 

m

ake

ce

r

tai

n

 wate

r

 flows th

r

o

u

gh the valve i

n

 the

p

r

ope

r

 di

r

ectio

n

; othe

r

wise, it will 

n

ot sh

u

t-

off.  The wo

r

ds “IN” a

n

d ‘OUT” a

r

e

i

m

p

r

i

n

ted o

n

 the valve di

r

ectly below the

po

r

t holes.  Co

nn

ect the wate

r

 s

u

pply hose

to the “IN” po

r

t.  Co

nn

ect the coppe

r

 wate

r

14

. *Reasse

m

ble pa

r

ts (see 

n

ote).

15

. With bea

m

 lock leve

r

 still locki

n

g pivot

bea

m

 off valve, ope

n

 b

r

ass sh

u

t-off valve.

16

. Adj

u

st co

n

t

r

ol valve at valve adj

u

st

m

e

n

t

sc

r

ew.

a

. Usi

n

g sc

r

ew d

r

ive

r

, t

urn

 valve adj

u

st

m

e

n

t

sc

r

ew (3/8” stai

n

less steel sc

r

ew i

n

 b

r

ass

b

u

shi

n

g)

un

til ve

r

y s

m

all st

r

ea

m

 flows f

r

o

m

the wate

r

 spo

u

t t

u

be a

n

d b

r

eaks –

u

p i

n

to

d

r

ops abo

u

t 3” below t

u

be o

u

tlet.  The

n

 t

urn

co

n

t

r

ol valve adj

u

st

m

e

n

t sc

r

ew 1/4 t

urn

co

un

te

r

-clockwise which will ca

u

se wate

r

 to

stop flowi

n

g.

Note:

  If, afte

r

 i

n

itial adj

u

st

m

e

n

t, wate

r

 does

n

ot co

m

pletely sh

u

t-off a

n

d d

r

ips, lock the

bea

m

 lock leve

r

 a

n

d t

urn

 the co

n

t

r

ol valve

adj

u

st

m

e

n

t sc

r

ew a

n

othe

r

 1/4 t

urn

 co

un

te

r

-

clockwise.  Co

n

ti

nu

e the p

r

ocess at 1/4 t

urn

i

n

te

r

vals

un

til wate

r

 sh

u

ts-off co

m

pletely

afte

r r

efilli

n

g.

17

. I

n

se

r

t stai

n

less steel bowl back i

n

to

wate

r

e

r

,

r

elease bea

m

 lock leve

r

 to allow

r

efilli

n

g a

n

d latch top cove

r

 to ho

u

si

n

g.

*Note:

It is 

mu

ch easie

r

 to i

n

stall the lead

co

un

te

r

 weight a

n

d co

n

t

r

ol valve adj

u

st

m

e

n

t

sc

r

ew o

n

to the pivot bea

m

 a

n

d cage 

AFTER

i

n

stalli

n

g pivot bea

m

 a

n

d cage to the c

r

oss

bea

m

 with the b

r

ass pivot shaft. 

WARNIN

G

! TURN OFF POWER WHEN 

SERVICIN

G

 WATERER.

Always t

urn

 off powe

r

 whe

n u

si

n

g a tool

to se

r

vice o

r m

ai

n

tai

n

 wate

r

e

r

 to

eli

m

i

n

ate

r

isk of elect

r

oc

u

tio

n

.  Wate

r

e

r

s

sho

u

ld be o

n

 dedicated ci

r

c

u

its.

WATER FILTER LOCATION

• Wate

r

 s

u

pply hose a

n

d sh

u

t-off valve sho

u

ld be located as show

n

 i

n

 diag

r

a

m

o

n

 left fo

r

 easie

r

 filte

r

 access a

n

d

m

axi

mum

 f

r

eeze p

r

otectio

n

.

• I

n

stall a la

r

ge cold wate

r

 filte

r

 i

n

 a 

n

o

n

-f

r

eeze locatio

n

 if yo

ur

 wate

r

 co

n

tai

n

s a

lot of deb

r

is a

n

d/o

r

 if yo

u

 have a la

r

ge

num

be

r

 of wate

r

e

r

s.

DO NOT

be

n

d/c

r

i

m

p coppe

r

 t

u

be leadi

n

g to b

r

ass sh

u

t-off valve.

TOP VIEW: COVER & BOWL REMOVED

CONTROL VALVE LOCATION

Coppe

r

Wate

r

Spo

u

t

T

u

be

Wate

r

S

u

pply

Hose

Pivot
Bea

m

C

r

oss Bea

m

C

r

oss Bea

m

B

r

ass Sh

u

t-off Valve

Co

n

t

r

ol Valve

Adj

u

st

m

e

n

t Sc

r

ew

Wate

r

S

u

pply

Hose

Bea

m

Lock
Leve

r

Co

un

te

r

 Weight

Pivot Bea

m

Coppe

r

 Wate

r

Spo

u

t T

u

be

Co

n

t

r

ol Valve 

Adj

u

st

m

e

n

t Sc

r

ew

Hole I

n

C

r

oss Bea

m

Co

n

t

r

ol Valve

B

r

ass

Pivot Shaft

QUESTIONS?

Pho

n

e: 888-844-6606

Mo

n

day-F

r

iday 7:30-5:00 CST

spo

u

t t

u

be to the “OUT” po

r

t. Befo

r

e

co

nn

ecti

n

g the wate

r

 s

u

pply li

n

e apply 

Teflo

n

® pipe tape to the th

r

eads of the 

b

r

ass fitti

n

gs. Avoid pipe joi

n

t co

m

po

un

d,

as so

m

e b

r

a

n

ds ha

r

de

n

 a

n

d fail ove

r

 ti

m

e.

Summary of Contents for 700 Series

Page 1: ......

Page 2: ...he water spout tube and breaks up into drops about 3 below tube outlet Then turn control valve adjustment screw counter clockwise which will cause water to stop flowing Then turn the screw an addition...

Page 3: ...of the brass pivot shaft and slide the brass pivot shaft out C The pivot beam and cage may then be removed as a unit 4 Remove the cover to the junction box and disconnect all wires in the junction bo...

Page 4: ...k the beam lock lever and turn the control valve adjustment screw another 1 4 turn counter clockwise Continue this process at 1 4 turn intervals until water shuts off completely after refilling C INSP...

Page 5: ...cal power OFF to the circuit will eliminate risk of electrocution B Freeze up may be the result of not having the electrical power switched on to the waterer This is common during the first cold weath...

Page 6: ...ld Conversely heat tapes often come with thermostats If the heat tapes thermostat is located too close to the waterers heater the heat tape my not be activated when necessary Waterline freeze up can r...

Page 7: ...from the drinking bowl Stamped on the counter weight is the word TOP which is to face up when installed Beam Lock Lever Locking the pivot beam with the beam lock lever prevents water from coming out...

Page 8: ...HOLE SHOULD EXTEND DOWN 4 6 FEET BELOW THE FROST LINE WATER AND ELECTRIC LINES DRAIN PIPE MODEL 730 24 8 ID DRAIN PIPE MODEL 760 24 10 ID DRAIN PIPE PVC OR ADS CORRUGATED NON PERFORATED PIPE TO KEEP H...

Page 9: ...flushed of debris filter may clog and control valve may not function properly resulting in dripping and overflow Install a large cold water filter in a non freeze location if your water contains a lo...

Page 10: ...ation WARNING ELECTRICAL INSTALLATION MAINTENANCE HEATER 755 785 A LICENSED ELECTRICIAN WILL DETERMINE A Type and size of service wire B grounding procedure and C proper fusing of heater GROUND WIRE T...

Page 11: ...o the IN port Connect the copper water 14 Reassemble parts see note 15 With beam lock lever still locking pivot beam off valve open brass shut off valve 16 Adjust control valve at valve adjustment scr...

Page 12: ......

Reviews: