HEATER & THERMOSTAT INSTALLATION DIA

G

RAMS

STRAIN RELIEF CONNECTOR

ELECTRICAL 
JUNCTION BOX

WATER
SPOUT
TUBE

HEATING
ELEMENT
(BELOW
CROSS BEAM)

HOLE IN
CROSS BEAM

HEAT SHEILD

CERAMIC
INSULATORS

THERMOSTAT

ELECTRICAL JUNCTION BOX COVER: 

• Replace old cove

r

 with 

n

ew cove

r

 p

r

ovided with heate

r

s & the

rm

ostats.

THERMOSTAT IS LOCATED IN ELECTRICAL JUNCTION BOX 
AS INDICATED IN DIA

G

RAM.

STRAIN RELIEF CONNECTOR PREVENTS HEATER CORD FROM BEIN

G

PULLED OUT OF JUNCTION BOX. SEE INSTRUCTIONS BELOW.

•Locate Co

nn

ecto

r

 o

n

 heate

r

 co

r

d with la

r

ge head of Co

nn

ecto

r

 o

n

 heati

n

g

ele

m

e

n

t side. Allow e

n

o

u

gh co

r

d o

n

 j

un

ctio

n

 box side fo

r

 wi

r

e

co

nn

ectio

n

s to be 

m

ade i

n

side j

un

ctio

n

 box.

•I

n

se

r

t Co

nn

ecto

r

 a

n

d heate

r

 co

r

d i

n

 j

un

ctio

n

 box (as i

n

dicated i

n

diag

r

a

m

)

u

si

n

g plie

r

s a

n

d fi

n

ge

r

s

un

til Co

nn

ecto

r

 s

n

aps i

n

 place.

•Test by p

u

lli

n

g o

n

 heate

r

 co

r

d towa

r

d heati

n

g ele

m

e

n

t. Co

nn

ecto

r

 a

n

d

heate

r

 co

r

d sho

u

ld

n

ot p

u

ll o

u

t of j

un

ctio

n

 box.

POWER SUPPLY MUST PROVIDE:

•A HOT wi

r

e which is co

nn

ected to 

r

e

m

ai

n

i

n

g BLACK wi

r

e of the

rm

ostat.

•A NEUTRAL wi

r

e which is co

nn

ected to WHITE wi

r

e of heate

r

.

•A 

G

ROUND wi

r

e which 

mu

st be co

nn

ected to the g

r

o

un

d sc

r

ew i

n

 the

ha

n

dy box. This will g

r

o

un

d both the wate

r

e

r

 a

n

d the heati

n

g ele

m

e

n

t.

INTENDED USE:

• The

rm

ostat Pa

r

t 758 is desig

n

ed fo

r

 both Models 730 & 760.

• Heate

r

 Pa

r

ts 755C & 755HA a

r

e desig

n

ed fo

r

 Model 730 Wate

r

e

r

s o

n

ly.

• Heate

r

 Pa

r

ts 785C & 785HA a

r

e desig

n

ed fo

r

 Model 760 Wate

r

e

r

s o

n

ly. 

• Heate

r

’s Pa

r

ts 755C & 785C co

m

e with Heati

n

g Ele

m

e

n

t, Heat Shield, 

Ce

r

a

m

ic I

n

s

u

lato

r

s, St

r

ai

n

 Relief Co

nn

ecto

r

 a

n

d Cove

r

 fo

r

 J

un

ctio

n

 Box.

• Do 

n

ot

u

se fo

r

 a

n

y othe

r

 applicatio

n

.

WARNING!

 ELECTRICAL INSTALLATION 

& MAINTENANCE 

HEATER #

755

785

A LICENSED ELECTRICIAN WILL DETERMINE

:

A)

 Type and size of service wire, 

B)

 grounding procedure, 

and C) proper fusing of heater.

GROUND WIRE:

The heating element is grounded to the 

waterer by a green ground screw at the factory.  The ground wire 
from the power service should be secured to the waterer with 
the second green ground screw provided in the handy box. When 
using wire-nuts, follow instruction on wire-nut box. Tape wire 
nuts to wire to prevent loosening. 

FUSING

:

Waterers must be individually fused. Do not over fuse. 

Consult a licensed electrician. Heating rating @ 120 volts AC.

DEDICATED CIRCUITS

 – Waterers must be on dedicated 

circuits. TURN POWER OFF after the Winter heating season when 
heaters are no longer needed (temperatures are consistently 
above freezing) or when performing maintenance on waterers.

Use a licensed electrician to install and maintain the 
Waterer, so you can be assured that you have complied 
with all national and local electrical codes and that you 
have not created a risk of electrocution or fire.  Improper 
installation or maintenance may result in serious injury or 
death for personnel or animals or damage to structures.

Heate

r

 & The

rm

ostat Wi

r

i

n

g Diag

r

a

m

WARNIN

G

!

TURN OFF ELECTRICITY WHEN SERVICIN

G

 WATERER 

Always t

urn

 off powe

r

 to wate

r

e

r

s whe

n u

si

n

g a tool to se

r

vice o

r

m

ai

n

tai

n

 wate

r

e

r

 to eli

m

i

n

ate

r

isk of elect

r

oc

u

tio

n

. Wate

r

e

r

s sho

u

ld be o

n

dedicated ci

r

c

u

its.

WARNIN

G

!

USE CARE NOT 

to spill wate

r

 o

n

 heati

n

g ele

m

e

n

t. Wate

r

 o

n

heati

n

g ele

m

e

n

t

r

ed

u

ces heate

r

 life a

n

d

m

ay lead to f

r

eeze-

u

p. Keep a

r

ea

below d

r

i

n

ki

n

g bowl as d

r

y a

n

d clea

n

 as possible.

TOP VIEW:

COVER & BOWL REMOVED

ELECTRICAL 

JUNCTION BOX

QUESTIONS?

Pho

n

e: 888-844-6606

Mo

n

day-F

r

iday 7:30-5:00 CST

10

Summary of Contents for 700 Series

Page 1: ......

Page 2: ...he water spout tube and breaks up into drops about 3 below tube outlet Then turn control valve adjustment screw counter clockwise which will cause water to stop flowing Then turn the screw an addition...

Page 3: ...of the brass pivot shaft and slide the brass pivot shaft out C The pivot beam and cage may then be removed as a unit 4 Remove the cover to the junction box and disconnect all wires in the junction bo...

Page 4: ...k the beam lock lever and turn the control valve adjustment screw another 1 4 turn counter clockwise Continue this process at 1 4 turn intervals until water shuts off completely after refilling C INSP...

Page 5: ...cal power OFF to the circuit will eliminate risk of electrocution B Freeze up may be the result of not having the electrical power switched on to the waterer This is common during the first cold weath...

Page 6: ...ld Conversely heat tapes often come with thermostats If the heat tapes thermostat is located too close to the waterers heater the heat tape my not be activated when necessary Waterline freeze up can r...

Page 7: ...from the drinking bowl Stamped on the counter weight is the word TOP which is to face up when installed Beam Lock Lever Locking the pivot beam with the beam lock lever prevents water from coming out...

Page 8: ...HOLE SHOULD EXTEND DOWN 4 6 FEET BELOW THE FROST LINE WATER AND ELECTRIC LINES DRAIN PIPE MODEL 730 24 8 ID DRAIN PIPE MODEL 760 24 10 ID DRAIN PIPE PVC OR ADS CORRUGATED NON PERFORATED PIPE TO KEEP H...

Page 9: ...flushed of debris filter may clog and control valve may not function properly resulting in dripping and overflow Install a large cold water filter in a non freeze location if your water contains a lo...

Page 10: ...ation WARNING ELECTRICAL INSTALLATION MAINTENANCE HEATER 755 785 A LICENSED ELECTRICIAN WILL DETERMINE A Type and size of service wire B grounding procedure and C proper fusing of heater GROUND WIRE T...

Page 11: ...o the IN port Connect the copper water 14 Reassemble parts see note 15 With beam lock lever still locking pivot beam off valve open brass shut off valve 16 Adjust control valve at valve adjustment scr...

Page 12: ......

Reviews: