background image

-15-

C-Series 1" & 1-1/4" WS1 Manual

Valve History

 STEP 1VH

Press 

p

and

q

 

simultaneously for 

three seconds and 

release. Then press 

p

and

q

 simultaneously 

and release. If screen in step 2VH does not appear in 5 

seconds the lock on the valve is activated. To unlock press 

q

NEXT

p

, and 

SET CLOCK

 in sequence, then press 

p

and

q

 simultaneously for 3 seconds and release. Then 

press 

p

and

q

 simultaneously and release.

 STEP 2VH

Software Version:

 

This display shows the 

software version of the 

valve. 

Press the 

NEXT

 button 

to go to Step 

3VH

.  

Press 

REGEN

 to exit Valve History.

 STEP 5VH

Days, Total Since  

Start-Up:

  This display 

shows the total days 

since startup. 

Press the 

NEXT

 button 

to go to Step 

6VH

.  

Press 

REGEN

 to return to previous step.

 STEP 6VH

Regenerations, Total 

Number Since Start-

Up:

  This display shows 

the total number of 

regenerations that have 

occurred since startup. 
Press the 

NEXT

 button to go to Step 

7VH

.  

Press 

REGEN

 to return to previous step.

 STEP 4VH

Gallons, Total Used 

Since Start-Up:

  This 

display shows the total 

gallons treated since 

startup. This display will 

equal zero if a water 

meter is not in stalled. 
Press the 

NEXT

 button to go to Step 

5VH

.  

Press 

REGEN

 to return to previous step.

 STEP 3VH

8

Flow Rate, Maximum 

Since Startup:

  This 

display shows the 

maximum flow rate 

in gallons per minute 

that has occurred since 

startup. This display will equal zero if a water meter is not 

installed. 
Press the 

NEXT

 button to go to Step 

4VH

.  

Press 

REGEN

 to return to previous step.

 STEP 7VH

Error Log:  

This display shows a history of the last 10 

errors generated by the control during operation. Press the 

p

or

q

 buttons to review each error recorded. 

Press the 

NEXT

 button to exit Valve History.  

Press 

REGEN

 to return to previous step.

or

8  

Values in steps 3VH through 7VH cannot be reset.

Summary of Contents for C Series

Page 1: ...C SERIES WS Programming Guide 1 1 1 4 Control Valve WS Series Models...

Page 2: ...tents Control Valve Function Cycles of Operation 3 4 System Set Up 5 6 Setting Options Table 7 Softener System Setup 8 9 Filter System Setup 9 10 Installer Displays Settings 11 User Displays Settings...

Page 3: ...can be cut above to below the top of tank thread The distributor tube is held in place by an o ring seal and the control valve also has a bayonet lock feature for upper distributor baskets The AC ada...

Page 4: ...es in Minutes WS1 WS1 25 Downflow Softener Grains Capacity lb NaCl 6000 to 3501 3500 to 2501 2500 to 1700 lbs NaCl cu ft resin2 Less than 7 5 7 5 to 12 More than 12 Backwash Normal 6 8 8 Regenerate 45...

Page 5: ...n 0 means the regeneration will occur at the preset regeneration time unless the gallons capacity reaches zero If the gallons capacity reaches zero the regeneration will begin 10 minutes after no wate...

Page 6: ...ber Any Number than estimated capacity Yes None Yes Yes Yes Any Number Off Capacity set to AUTO and the Regeneration Time Option set to Normal or Normal on 0 The actual reserve capacity is compared to...

Page 7: ...cause regeneration will always occur when volume capacity reaches 0 Any Number On 0 oFF Reserve capacity NOT automatically estimated Regeneration occurs immediately when volume capacity reaches 0 Time...

Page 8: ...per regeneration using q or p Press NEXT to go to Step 5S Press REGEN to return to previous step STEP 5S Backwash Select NORMAL or LONGER using q or p See Tables 2 or 3 for backwash times Press NEXT...

Page 9: ...ied number of days between regenerations is reached which ever comes first or after 10 minutes of no water usage when the gallon capacity reaches 0 zero See Setting Options Table for more detail Press...

Page 10: ...ackwashes 8 minutes each LONGER for one LONGER backwash 16 minutes or LONGER 2 for two LONGER backwashes 12 minutes each See Tables 5 and 6 for additional details Press NEXT to go to Step 5F Press REG...

Page 11: ...using porq buttons This display will not be shown if on 0 is selected in the OEM Setup Press NEXT to exit Installer Display Settings Press REGEN to return to previous step To initiate a manual regener...

Page 12: ...d water when the regeneration has been completed Manual Regeneration Sometimes there is a need to regenerate the system sooner than when the system calls for it usually referred to as manual regenerat...

Page 13: ...If the word ERROR and a number are alternately flashing on the display contact the OEM for help This indicates that the valve was not able to function properly STEP 1D Press porq simultaneously for t...

Page 14: ...Used Since Last Reset The total number of gallons used since last reset will be displayed This display will equal zero if a water meter is not installed Press the NEXT button to go to Step 9D Press R...

Page 15: ...hows the total number of regenerations that have occurred since startup Press the NEXT button to go to Step 7VH Press REGEN to return to previous step STEP 4VH Gallons Total Used Since Start Up This d...

Page 16: ...embly Not Shown CL3186 AC Adapter 120V 12V CL3186EU AC Adapter 220 240V 12V EU 1 CL3186UK AC Adapter 220 240V 12V UK CL3186 01 AC Adapter Cord Only When replacing the battery align positives and push...

Reviews: