background image

-12-

C-Series 1" & 1-1/4" WS1 Manual

User Display Settings

 General Operation

When the system is operating one 

of two displays will be shown. 

Pressing 

NEXT

 will alternate 

between the displays. One of the 

displays is always the current 

time of day. The second display 

is one of the following: days 

remaining or gallons remaining. 

Days remaining is the number of 

days left before the system goes 

through a regeneration cycle. 

Capacity remaining is the number 

of gallons that will be treated 

before the system goes through a regeneration cycle. 

The user can scroll between the displays as desired.
If the system has called for a regeneration that 

will occur at the preset time of regeneration, the 

words REGEN TODAY will appear on the display.
When water is being treated (i.e. water is flowing 

through the system) the word “Softening” or “Filtering” 

flashes on the display if a water meter is installed.

 Regeneration  

 Mode

Typically a 

system is set 

to regenerate at 

a time of low water usage. An example of a time 

with low water usage is when a household is asleep. 

If there is a demand for water when the system 

is regenerating, untreated water will be used.
When the system begins to regenerate, the display 

will change to include information about the step of the 

regeneration process and the time remaining for that 

step to be completed. The system runs through the steps 

automatically and will reset itself to provide treated 

water when the regeneration has been completed.

 Manual  

 Regeneration

Sometimes there 

is a need to 

regenerate the 

system sooner 

than when 

the system calls for it, usually referred to as manual 

regeneration. There may be a period of heavy water usage 

because of guests or a heavy laundry day.
To initiate a manual regeneration at the preset delayed 

regeneration time, when the regeneration time option is 

set to “NORMAL” or “ on 0”, press and release 

REGEN

”. The words “REGEN TODAY” will flash on the 

display to indicate that the system will regenerate at 

the preset delayed regeneration time. If you pressed the 

REGEN

” button in error, pressing the button again will 

cancel the request. 

Note:

   If the regeneration time option is set to “on 0”  

there is no set delayed regeneration time so 

“REGEN TODAY” will not activate if “REGEN”  

button is pressed.

To initiate a manual regeneration immediately, press and 

hold the “

REGEN

” button for three seconds. The system 

will begin to regenerate immediately. The request cannot 

be cancelled.

Note:

   For softeners, if brine tank does not contain salt, 

fill with salt and wait at least two hours before 

regenerating.

REGEN TODAY will be 

displayed if a regeneration 

is expected “Tonight.”

 Power Loss

If the power goes out, the system will keep time for up to 

8 hours or until the battery is depleted. If a power outage 

of more than 8 hours occurs, the time of day will flash on 

and off which indicates the time of day should be reset. 

The system will remember the rest. If a power outage 

lasts less than 8 hours and the time of day flashes on and 

off, the non rechargeable battery should be replaced.

Summary of Contents for C Series

Page 1: ...C SERIES WS Programming Guide 1 1 1 4 Control Valve WS Series Models...

Page 2: ...tents Control Valve Function Cycles of Operation 3 4 System Set Up 5 6 Setting Options Table 7 Softener System Setup 8 9 Filter System Setup 9 10 Installer Displays Settings 11 User Displays Settings...

Page 3: ...can be cut above to below the top of tank thread The distributor tube is held in place by an o ring seal and the control valve also has a bayonet lock feature for upper distributor baskets The AC ada...

Page 4: ...es in Minutes WS1 WS1 25 Downflow Softener Grains Capacity lb NaCl 6000 to 3501 3500 to 2501 2500 to 1700 lbs NaCl cu ft resin2 Less than 7 5 7 5 to 12 More than 12 Backwash Normal 6 8 8 Regenerate 45...

Page 5: ...n 0 means the regeneration will occur at the preset regeneration time unless the gallons capacity reaches zero If the gallons capacity reaches zero the regeneration will begin 10 minutes after no wate...

Page 6: ...ber Any Number than estimated capacity Yes None Yes Yes Yes Any Number Off Capacity set to AUTO and the Regeneration Time Option set to Normal or Normal on 0 The actual reserve capacity is compared to...

Page 7: ...cause regeneration will always occur when volume capacity reaches 0 Any Number On 0 oFF Reserve capacity NOT automatically estimated Regeneration occurs immediately when volume capacity reaches 0 Time...

Page 8: ...per regeneration using q or p Press NEXT to go to Step 5S Press REGEN to return to previous step STEP 5S Backwash Select NORMAL or LONGER using q or p See Tables 2 or 3 for backwash times Press NEXT...

Page 9: ...ied number of days between regenerations is reached which ever comes first or after 10 minutes of no water usage when the gallon capacity reaches 0 zero See Setting Options Table for more detail Press...

Page 10: ...ackwashes 8 minutes each LONGER for one LONGER backwash 16 minutes or LONGER 2 for two LONGER backwashes 12 minutes each See Tables 5 and 6 for additional details Press NEXT to go to Step 5F Press REG...

Page 11: ...using porq buttons This display will not be shown if on 0 is selected in the OEM Setup Press NEXT to exit Installer Display Settings Press REGEN to return to previous step To initiate a manual regener...

Page 12: ...d water when the regeneration has been completed Manual Regeneration Sometimes there is a need to regenerate the system sooner than when the system calls for it usually referred to as manual regenerat...

Page 13: ...If the word ERROR and a number are alternately flashing on the display contact the OEM for help This indicates that the valve was not able to function properly STEP 1D Press porq simultaneously for t...

Page 14: ...Used Since Last Reset The total number of gallons used since last reset will be displayed This display will equal zero if a water meter is not installed Press the NEXT button to go to Step 9D Press R...

Page 15: ...hows the total number of regenerations that have occurred since startup Press the NEXT button to go to Step 7VH Press REGEN to return to previous step STEP 4VH Gallons Total Used Since Start Up This d...

Page 16: ...embly Not Shown CL3186 AC Adapter 120V 12V CL3186EU AC Adapter 220 240V 12V EU 1 CL3186UK AC Adapter 220 240V 12V UK CL3186 01 AC Adapter Cord Only When replacing the battery align positives and push...

Reviews: