-12-
C-Series 1" & 1-1/4" WS1 Manual
User Display Settings
General Operation
When the system is operating one
of two displays will be shown.
Pressing
NEXT
will alternate
between the displays. One of the
displays is always the current
time of day. The second display
is one of the following: days
remaining or gallons remaining.
Days remaining is the number of
days left before the system goes
through a regeneration cycle.
Capacity remaining is the number
of gallons that will be treated
before the system goes through a regeneration cycle.
The user can scroll between the displays as desired.
If the system has called for a regeneration that
will occur at the preset time of regeneration, the
words REGEN TODAY will appear on the display.
When water is being treated (i.e. water is flowing
through the system) the word “Softening” or “Filtering”
flashes on the display if a water meter is installed.
Regeneration
Mode
Typically a
system is set
to regenerate at
a time of low water usage. An example of a time
with low water usage is when a household is asleep.
If there is a demand for water when the system
is regenerating, untreated water will be used.
When the system begins to regenerate, the display
will change to include information about the step of the
regeneration process and the time remaining for that
step to be completed. The system runs through the steps
automatically and will reset itself to provide treated
water when the regeneration has been completed.
Manual
Regeneration
Sometimes there
is a need to
regenerate the
system sooner
than when
the system calls for it, usually referred to as manual
regeneration. There may be a period of heavy water usage
because of guests or a heavy laundry day.
To initiate a manual regeneration at the preset delayed
regeneration time, when the regeneration time option is
set to “NORMAL” or “ on 0”, press and release
“
REGEN
”. The words “REGEN TODAY” will flash on the
display to indicate that the system will regenerate at
the preset delayed regeneration time. If you pressed the
“
REGEN
” button in error, pressing the button again will
cancel the request.
Note:
If the regeneration time option is set to “on 0”
there is no set delayed regeneration time so
“REGEN TODAY” will not activate if “REGEN”
button is pressed.
To initiate a manual regeneration immediately, press and
hold the “
REGEN
” button for three seconds. The system
will begin to regenerate immediately. The request cannot
be cancelled.
Note:
For softeners, if brine tank does not contain salt,
fill with salt and wait at least two hours before
regenerating.
REGEN TODAY will be
displayed if a regeneration
is expected “Tonight.”
Power Loss
If the power goes out, the system will keep time for up to
8 hours or until the battery is depleted. If a power outage
of more than 8 hours occurs, the time of day will flash on
and off which indicates the time of day should be reset.
The system will remember the rest. If a power outage
lasts less than 8 hours and the time of day flashes on and
off, the non rechargeable battery should be replaced.