   Safety information and warnings

 

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, 
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

16.  Use this unit in the manner intended by the manufacturer. If you have 

any questions, please call customer service.

17.  Installation work and electrical wiring must be done by a qualifed 

person in accordance with all applicable codes and standards, 
including fire-rated construction.

18.  Sufficient air is needed for proper combustion and exhausting  

of gasses through the chimney (flu) of fuel burning equipment  
to prevent back drafting. Follow the heating equipment manufacturers 
guideline and safety standards such as those published by the NFPA 
(National Fire Protection Association) and ASHRAE (American 
Society for Heating Refrigeration and Air Conditioning Engineers)  
and the local building code authorities.

19.  Do not install in a ceiling with insulation greater than R40.
20.  Be careful not to damage existing wiring when cutting or driling into 

walls or ceilings. When cutting the ceiling, do not damage electrical 
wiring and other hidden utilities.

21.  Switch power off at service panel and lock the service disconnecting 

means to prevent power from being switched on accidentally. When 
the service disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel.

22.  If this unit is to be installed over a tub or shower, it must be marked 

as appropriate for the application. When the fan is to be installed  
in the bathroom, the fan and the tub need to be more than 3’ (1 m) 
from each other, the fan required to install at the other side of the 
tub in ceiling. Acceptable for use over a bathtub or shower when 
installed in a GFCI protected branch circuit.

23.  DO NOT use rigid conduit for the installation.
24.  Duct work should be installed in a straight line with minimal bends.
25.  Duct work size must be the same size as the discharge and should 

not be reduced. Reducing the duct size may increase fan noise.

26.  For CUL only: Mount with the lowest moving parts at least  

8’ 2" (2.5 m) above floor or grade level.

 

Specifications

Model no.

V

Hz

Duct 

diameter

Noise (sone)

Power 

consumption

Speed (RPM)

Air direction

Weight

3291021 

(BPT14-24ALB3)

120

60

4”  

(10.2 cm)

1.2

72 W

1,022

110 CFM

10.49 lb  

(4.76 kg)

  For an average ductwork which is 10’ to 15’ (3 m to 4.6 m) long, 4” (10.2 cm) in diameter with the assumption of a 8’ (2.4 m) high ceiling.

  LED bulbs: 2 x GU24 9 W.

  Recommended for use in rooms up to 135 ft

2

 (12.54 m

2

).

  If the area is larger, it is recommended to use a fan providing a greater CFM.

 

Dimensions

Ceiling opening (L)

Ceiling opening (W)

Ceiling opening (D)

Housing dimension (L)

Housing dimension (W)

Housing dimension (D)

1

/

4

”  

(23.5 cm)

1

/

4

”  

(23.5 cm)

8”  

(20.3 cm)

9”  

(23 cm)

9”  

(23 cm)

11

/

16

”  

(19.5 cm)

Note : Be careful to cut the hole exactly to ensure that the screen will cover it properly.

Summary of Contents for PRO 3291021

Page 1: ...ateur de salle de bains avec clairage 110 PCM IMPORTANT Veuillez lire les instructions qui suivent et conserver ce guide AVIS l installateur remettez ce guide au propri taire Au propri taire conservez...

Page 2: ...ional de l lectricit NEC et la loi sur la sant et s curit du travail 5 Coupez toujours l alimentation lectrique avant une maintenance sur le ventilateur le moteur ou la bo te de d rivation 6 Veuillez...

Page 3: ...des appareils combustible dans le but d viter tout refoulement Veuillez respecter les directives du fabricant de l quipement de chauffage et les normes de s curit publi es par l Association nationale...

Page 4: ...rtir du panneau lectrique Installation I sur solive 1 Ins rez les supports dans le bo tier ill A Supports pour suspension Support I 2 vis Support II Conduit Bo te de jonction Illustration A Illustrati...

Page 5: ...ble tuyau ni autre obstacle n emp chera l installation 1 Pour installer le ventilateur suivez les tapes 1 et 2 du paragraphe Installation I page 4 2 Retirez la partie du plafond 3 Installez le bo tie...

Page 6: ...t aux conditions cumulatives suivantes 1 l acheteur doit s adresser au d taillant aupr s de qui il a effectu son achat 2 l acheteur doit remettre au d taillant la ou les pi ces d fectueuses ou encore...

Page 7: ...ation Guide 3291021 Bathroom Fan with Light 110 CFM IMPORTANT Please read and keep this guide NOTICE To the installer you must leave this guide with the owner To the owner keep this guide for future r...

Page 8: ...perature will exceed 40 C 104 F 3 Do not bend or kink the power wires 4 Follow all local building safety and electrical codes as well as NEC National Electrical Code and OSHA Occupational Safety and H...

Page 9: ...curely fasten a prominent warning device such as a tag to the service panel 22 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application When the fan is...

Page 10: ...t mounting Insert the support brackets into the slots on the fan housing Fig A Insert support brackets Support bracket I 2 screws Support bracket II Duct Wiring box Figure A Figure C Figure B 2 Instal...

Page 11: ...g or other obstructions can interfere with the installation 1 To install the fan housing follow the steps 1 and 2 described in Installation I page 4 2 Remove ceiling section 3 Install fan housing 4 Co...

Page 12: ...efective part or parts or the Product to the retailer 3 the purchaser must provide the retailer the invoice as proof of purchase and date of purchase of the Product 4 the purchaser must supply the Pro...

Reviews: