Table 2 

LOCAL INPUTS OPERATION 

(Wall-mounted push-button panel)

 

Combination 

Effective Function 

Input 1 

Up / Stop 

Input 2 

Down / Stop 

Input 1 and 2 simultaneously 

Step / Step 

3. 

D

EFINITION OF THE FUNCTIONS

 

3.1. 

 “Lights Control” mode functions 

“LIGHTS CONTROL” MODE FUNCTIONS 

Function 

Description 

Monostable

 

The  selected  output  is  activated  when  any  one  of  the  corresponding 
remote control keys is pressed. 
If  the  output  is  already  active  (for  example  during  the  corresponding 
activation of the local control), a subsequent activation command (e.g.:  
pressing the corresponding key of the remote control) is ignored. 

Bistable 

The outputs are controlled in the following manner: 

-  first  time  the  key  of  the  remote  control  is  pressed:  the  output 

memorized on the corresponding key is activated; 

-  second time the key of the remote control is pressed: the output is 

de-activated. 

Furthermore, when the local switch is closed and the relative output is 
active, if the user presses the corresponding key of the remote control, 
the output is de-activated; when the switch is opened again, the output 
is activated again. 
Finally,  the  bistable  mode  is  the  factory-default  mode  for  the  module 
and is automatically reset after the memory has been erased. 

Timed 

In this mode the selected output is activated remotely when any of the 
corresponding  keys  of  the  remote  control  is  pressed  and  remains 
active for a time interval (time-out) memorized in the device. The output 
can  be  de-activated  by  pressing  the  key,  after  a  minimum  time  of  5 
seconds. 
The output can be controlled similarly locally as well. (E.g.: if the switch 
is  closed,  the  output  is  activated  for  the  set  time,  after  which  it  is  de-
activated.  If  the  switch  is  opened  afterwards,  the  output  is  activated 
and  the  timer  starts  over.  The  change  of  state  of  the  switch  is 
equivalent to pressing the key of the remote control: it causes the de-
activation of the output, after a minimum time of 5 seconds. 

3.2. 

“Motor control” mode functions 

In  the  motor  version  there  is  also  a  time-out  that  can  be  programmed  by  the  user,  the 
purpose of which is to interrupt in any case the command received (from both TX and the 
local inputs) in order to protect the motor. 

12 

The relays cannot be activated simultaneously. Any change of activation will be preceded 
by a de-activation of both relays for a minimum period of 500 ms. 
 

“MOTOR CONTROL” MODE FUNCTIONS 

Function 

Description 

Step / Step

 

The  motor  executes  the  Step  by  Step  command,  i.e.,  with  each  new 
reception  of the radio code /  wall-mounted control it  will  have to respect 
the sequence of 

UP

-

STOP

-

DOWN

-

STOP

-..... 

Up / Stop 

Upon reception of the command the receiver activates the up relay for the 
set working time, upon reception of a second command it de-activates the 
relay. 

Down / Stop 

Upon reception of the command the receiver activates the down relay for 
the set working time, upon reception of a second command it de-activates 
the relay. 

Deadman's 
Step / Step 

Upon reception of the command the receiver behaves as in command 1 
without,  however,  the  stop  command  between  open  and  close. 
Furthermore, the activation of the relay is executed only for the period in 
which the receiver acknowledges the radio code / local button. 
The  relay  is  de-activated  if  the  command  in  no  longer  present  for  a 
continuous period of 500 ms or the maximum working time has expired. 

Deadman's 
Up 

Upon reception of the command the receiver activates the up relay. When 
the radio code / local control is no longer received for a continuous period 
of  500  ms  or  the  maximum  working  time  is  exceeded,  the  receiver  de-
activates the relay. 

Deadman's 
Down 

Upon  reception  of  the  command  the  receiver  activates  the  down  relay. 
When the radio code / local control is no longer received for a continuous 
period of 500 ms or the maximum working time is exceeded, the receiver 
de-activates the relay. 

Stop 

Upon  reception  of  the  command  the  receiver  de-activates  the  up  and 
down relays. 

Up 

Upon reception of the command the receiver activates the up relay for a 
maximum time equal to the set working time. 

Down 

Upon reception of the command the receiver activates the down relay for 
a maximum time equal to the set working time. 

4. 

P

ROCEDURES

 

ERASING THE MEMORY OF THE RR2-M RECEIVER 

Step 

Description 

Example 

Press  and  hold  the  programming  button  of  the  MINI-RX 
until  the  LED  of  the  receiver  blinks  once  and  the  buzzer 
emits one beep. 

> 3s 

 
 

x 1  +  

x 1 

About  1  second  after  the  button  is  released  the  LED  on 
the receiver blinks 5 times. 

x … 

Summary of Contents for RR2-M

Page 1: ...y qualified personnel from a service centre authorised by the manufacturer Do not use if repair or adjustment is required CAUTION Disconnect the power supply during cleaning or maintenance operations...

Page 2: ...f the device This device is intended only and exclusively for the use for which it was designed and the manufacturer cannot be held liable for The product is powered at a hazardous voltage All electri...

Page 3: ...rovided in this manual There may be hazards for your health and safety during installation The control devices buttons or switches and connection cables must have suitable insulation characteristics f...

Page 4: ...DIRECTIONS THESE INSTRUCTIONS ARE INTENDED FOR TECHNICAL AND SPECIALIZED PERSONNEL THUS BASIC SAFETY AND WORKING TECHNIQUES ARE NOT DISCUSSED Diagram 1 Directions for controlling 2 independent loads...

Page 5: ...a low tone for second if there is at least one remote control memorized two blinks of the LED accompanied by two low tones if there is no remote control memorized The receiver is able to receive remot...

Page 6: ...nd the local inputs in order to protect the motor 12 The relays cannot be activated simultaneously Any change of activation will be preceded by a de activation of both relays for a minimum period of 5...

Page 7: ...7 To end the procedure wait for the time out of 10 seconds 8 End SELECTING THE DEVICE MODE Warning The radio remote controls in memory will also be erased Step Description Example 1 Press and hold th...

Page 8: ...s of activation to be set Press1 time 0 Hours Press again 1 Hour Press10 times 9 Hours The receiver emits 2 blinks and 2 beeps each time the button is pressed x n x 2 x 2 16 4 Confirm the operating ho...

Page 9: ...rogramming button of the MINI RX two times The LED of the receiver blinks twice and the buzzer emits 2 beeps every 2 seconds x 2 x 2 x 2 18 2 Hold the programming button of the MINI RX pressed The LED...

Page 10: ...to natural wear and tear or corrosion overload however temporary etc The manufacturer will accept no responsibility for eventual damage incurred by erroneous assembly manoeuvre or insertion excessive...

Reviews: