11
Table 2
LOCAL INPUTS OPERATION
(Wall-mounted push-button panel)
Combination
Effective Function
Input 1
Up / Stop
Input 2
Down / Stop
Input 1 and 2 simultaneously
Step / Step
3.
D
EFINITION OF THE FUNCTIONS
3.1.
“Lights Control” mode functions
“LIGHTS CONTROL” MODE FUNCTIONS
Function
Description
Monostable
The selected output is activated when any one of the corresponding
remote control keys is pressed.
If the output is already active (for example during the corresponding
activation of the local control), a subsequent activation command (e.g.:
pressing the corresponding key of the remote control) is ignored.
Bistable
The outputs are controlled in the following manner:
- first time the key of the remote control is pressed: the output
memorized on the corresponding key is activated;
- second time the key of the remote control is pressed: the output is
de-activated.
Furthermore, when the local switch is closed and the relative output is
active, if the user presses the corresponding key of the remote control,
the output is de-activated; when the switch is opened again, the output
is activated again.
Finally, the bistable mode is the factory-default mode for the module
and is automatically reset after the memory has been erased.
Timed
In this mode the selected output is activated remotely when any of the
corresponding keys of the remote control is pressed and remains
active for a time interval (time-out) memorized in the device. The output
can be de-activated by pressing the key, after a minimum time of 5
seconds.
The output can be controlled similarly locally as well. (E.g.: if the switch
is closed, the output is activated for the set time, after which it is de-
activated. If the switch is opened afterwards, the output is activated
and the timer starts over. The change of state of the switch is
equivalent to pressing the key of the remote control: it causes the de-
activation of the output, after a minimum time of 5 seconds.
3.2.
“Motor control” mode functions
In the motor version there is also a time-out that can be programmed by the user, the
purpose of which is to interrupt in any case the command received (from both TX and the
local inputs) in order to protect the motor.
12
The relays cannot be activated simultaneously. Any change of activation will be preceded
by a de-activation of both relays for a minimum period of 500 ms.
“MOTOR CONTROL” MODE FUNCTIONS
Function
Description
Step / Step
The motor executes the Step by Step command, i.e., with each new
reception of the radio code / wall-mounted control it will have to respect
the sequence of
UP
-
STOP
-
DOWN
-
STOP
-.....
Up / Stop
Upon reception of the command the receiver activates the up relay for the
set working time, upon reception of a second command it de-activates the
relay.
Down / Stop
Upon reception of the command the receiver activates the down relay for
the set working time, upon reception of a second command it de-activates
the relay.
Deadman's
Step / Step
Upon reception of the command the receiver behaves as in command 1
without, however, the stop command between open and close.
Furthermore, the activation of the relay is executed only for the period in
which the receiver acknowledges the radio code / local button.
The relay is de-activated if the command in no longer present for a
continuous period of 500 ms or the maximum working time has expired.
Deadman's
Up
Upon reception of the command the receiver activates the up relay. When
the radio code / local control is no longer received for a continuous period
of 500 ms or the maximum working time is exceeded, the receiver de-
activates the relay.
Deadman's
Down
Upon reception of the command the receiver activates the down relay.
When the radio code / local control is no longer received for a continuous
period of 500 ms or the maximum working time is exceeded, the receiver
de-activates the relay.
Stop
Upon reception of the command the receiver de-activates the up and
down relays.
Up
Upon reception of the command the receiver activates the up relay for a
maximum time equal to the set working time.
Down
Upon reception of the command the receiver activates the down relay for
a maximum time equal to the set working time.
4.
P
ROCEDURES
ERASING THE MEMORY OF THE RR2-M RECEIVER
Step
Description
Example
1
Press and hold the programming button of the MINI-RX
until the LED of the receiver blinks once and the buzzer
emits one beep.
> 3s
x 1 +
x 1
2
About 1 second after the button is released the LED on
the receiver blinks 5 times.
x …