Fig. 11

Fig. 12

Fig. 13

Fig. 15

Fig. 14

rapid release hook inserted onto the pin Ø4x32 

(provi-

ded) in median position (Fig. 6).

H.

Mount the actuator onto the brackets by inserting the
two openings at each side onto the corresponding pins
on the brackets.

I.

Rotate the actuator 90°, bring the chain terminal up
to the bracket and insert the pin into the opening on
the bracket. Insert the rapid release hook into the
bracket. For the first few times, this may fairly stiff, but
in time the pieces involved will adapt to their posi-
tions.

J.

Check that the exit on the chain is perfectly aligned
with the bracket. If the chain is not aligned with the
bracket, loosen the fixing screws and reposition the
bracket correctly.

K.

Check all electrical connections with the diagram on
the label attached to the lead.

L.

Carry out a complete check of opening and closure of
the window. Once the closure phase has been comple-
ted, check that the window frame is completely closed
by checking the pressure on the weather strips.

M.

On re-entry the actuator limit switch functions auto-
matically. The device exerts a traction force of over
300 N to guarantee perfect sealing up of the weather
strips.

5.2. Assembly on transom window.

A.

Before starting, check that there are at least two
mechanical compass safety stops or other form of
stops connected to the frame, and ensure that the
stops can prevent any accidental fall of the window.
Your safety is at hand.

B.

Pencil in an “X” over the centre line of the window
frame 

(Fig. 7) or divide the frame in 3 parts in case of

Kato Syncro mounting.

C.

Select the correct form of brackets

(Fig. 8).

D.

Attach the adhesive template to the window frame
(fixed part) and line axis up with the centre line “X”
traced earlier 

(Fig. 9). 

Warning:

for window frames not

on the same plane, cut the part of the adhesive tem-
plate coloured in grey and fix this to the moveable
part of the window frame, taking care to keep it in the
same position.

E.

Bore holes in the window frame at the points indicated
on the adhesive template 

(Fig. 10).

F.

Assemble the two brackets with the distancer 

(to help

position correctly. Once it has served its purpose it
can be removed). Mount the supports onto the frame
with the appropriate screws provided. Check that eve-
rything is aligned both horizontally and vertically.

G.

Mount the bracket for outward opening windows onto the moveable part of the
frame in accordance with the markings indicated on the adhesive template.

H.

Complete assembly of the chain terminal with the rapid release hook inserted onto
the provided pin Ø4x32 in median position 

(Fig. 11).

I.

Mount the actuator onto the brackets by inserting the two openings at each side
onto the corresponding pins on the brackets.

J.

Rotate the actuator 90°, bring the chain terminal up to the bracket and insert the
pin into the opening on the bracket. Insert the rapid release hook into the bracket.

K.

Check that the exit on the chain is perfectly aligned with the bracket. If the chain is
not aligned with the bracket, loosen the fixing screws and reposition the bracket
correctly.

L.

Check all electrical connections with the diagram on the label attached to the lead.

M.

Carry out a complete check of opening and closure of the window. Once the closu-
re phase has been completed, check that the window frame is completely closed by
checking the pressure on the weather strips.

N.

On re-entry the actuator limit switch functions automatically. The device exerts a
traction force of over 300 N to guarantee perfect sealing up of the weather strips.

5.3. Vertical assembly of the actuator on outward opening window.

A.

Pencil in an “X” over the centre line of the window frame 

(Fig. 12) or divide the

frame in 3 parts in case of Kato Syncro mounting.

B.

Select the correct form of brackets 

(Fig. 13).

C.

Fold the adhesive template along the green dotted line and keep in position at 90°.
Attach one part to the window frame

(fixed part), taking care to line up the axis with

the “X” previously pencilled in on the central line and line the folded part up against
the moveable part of the frame. 

Warning:

as various different applications are pos-

sible, place the actuator in a central position and adjust the positions of the brac-
kets, taking care to keep the actuator aligned with the window section.

D.

Bore holes into the window frame at the points indicated  

(Fig. 14).

E.

Mount the bracket for outward opening windows onto the moveable part of the
frame in accordance with the markings indicated on the adhesive template.

F.

Complete assembly of the chain terminal with the rapid release hook inserted onto
the provided pin Ø4x32 in median position 

(Fig. 15).

G.

Mount the two brackets on to the sides of the actuator.

H.

Position the actuator onto the window frame and line up with the holes bored ear-
lier. Fix the actuator in position with the screws provided.

I.

Bring the chain terminal up to the bracket and insert the pin into the hole on the
bracket. Attach the rapid release hook to the bracket.

J.

Check that the exit of the chain is perfectly aligned with the bracket. If the chain is
not aligned, loosen the fixing screws and reposition the bracket correctly.

K.

Check all electrical connections with the diagram on the label attached to the lead.

L.

Carry out a complete check of opening and closure of the window. Once the closu-
re phase has been completed, check that the window frame is completely closed by
checking the pressure on the weather strips.

M.

On re-entry the actuator limit switch functions automatically. The device exerts a
traction force of over 300 N to guarantee perfect sealing up of the weather strips.

Summary of Contents for KATO SYNCRO

Page 1: ...and that all the following standards have been applied EN 55014 1 EN 61000 2 3 EN 61000 3 3 EN 55014 2 Last two figures of the year of the CE marking 04 KATO chain operated actuator 230V o 24V Mason V...

Page 2: ...tured in safe materials in compliance with the requirements of legislation in force When correctly mounted installed and used in accordance with the present instructions our products constitute no dan...

Page 3: ...ening of 3 mm should be installed at the start of the command line Never clean the device with solvents or jets of water Never immerse appliance in water Warning in the event of damage or malfunction...

Page 4: ...e hung is over 405 mm in length Anything shorter than this will not allow for assembly of the actuator Ensure that all load limits for the actuator are always respected in accordance with the specific...

Page 5: ...ins on the brackets J Rotate the actuator 90 bring the chain terminal up to the bracket and insert the pin into the opening on the bracket Insert the rapid release hook into the bracket K Check that t...

Page 6: ...on indications For harness please follow the following diagrams After connecting the electricity supply to the control button bipolar with arrows if possible check that the up key function opens the w...

Page 7: ...VE OFF OFF SINGLE ON ON Programming repetition In the event of actuators don t run synchronized we suggest to neutralize and repeat the programming acting in this way Take the two actuators programmin...

Page 8: ...ace any defective parts due to bad quality materials or construction defects This warranty covers products or their single parts for a period of 2 years from the date of purchase The warranty is valid...

Reviews: