Check all connections for gas leaks with soap and
water. DO NOT use a naked flame for detecting
leaks.
¡
Ignite all burners both individually and concurrently
to ensure correct operation of gas valves, burners
and ignition.
¡
Turn gas taps to low flame position and observe sta-
bility of the flame for each burner individually and all
together.
¡
Adhere the duplicate data plate to an accessible
location near the hotplate.
¡
When satisfied with the hotplate, instruct the user on
the correct method of operation.
¡
In case the appliance fails to operate correctly after
all checks have been carried out, refer to the author-
ised service provider in your area.
When being repaired, the appliance must always be
disconnected from the mains supply; if required, notify
our customer service.
2.8 Converting the cooktop from Natural
Gas to ULPG
All work involved in installation, setting and adaptation
to a different gas type must be carried out by a li-
censed gas fitter and must comply with current regula-
tions and the conditions laid down by the local gas
company.
Before conversion the cooktop must be disconnected
from the electricity and gas valves must be turned to
the OFF position.
Tools
Contact technical customer service to purchase the rel-
evant tools.
Removal lever
483196
Removing the cover
1.
Remove the pan supports, burner caps, distributors
and rotary knobs.
2.
Undo the screws on the burners.
3.
If required, place the removal lever on the marked
areas and loosen the front clip fastener.
4.
Carefully remove the cover.
Removing the circuit board
Tip:
The circuit board is secured to the holder by
fastening pins at the sides and in the middle. Push the
fastening pins carefully without damaging them. If one
of the pins breaks, the entire holder must be replaced.
ATTENTION!
The circuit board can be damaged by improper hand-
ling.
▶
Handle the circuit board carefully.
▶
Use anti-static shields or hold the circuit board at
the edges.
▶
Never touch the surfaces of the circuit board on
which there are components or conducting tracks.
1.
Undo the fastening pins on one side.
2.
Release the fastening pins in the middle by pressing
on them from both sides with your fingers.
3.
Undo the fastening pins on the other side and re-
move the circuit board.
Adjusting the taps
Requirement:
The upper part of the appliance and the
circuit board are removed.
→
"Removing the circuit board", Page 10
1.
Remove the cylindrical parts and springs from the
fittings spindle.
2.
Adjust the bypass screws:
‒
A: For ULPG, the bypass screws must be
tightened properly.
‒
B: For Natural Gas, the bypass screws must fin-
ish flush with the fitting.
Injectors