Eliminating minor faults
yourself
Before you call Customer service:
Please check whether you can eliminate the fault your
self based on the following information.
Customer service will charge you for advice even if the
appliance is still under guarantee!
Fault
Possible cause
Remedial action
Appliance is not working
Mains plug has not been inserted properly.
Check whether the power cord is plugged into
the power outlet properly.
The fuse has been switched off or is defective.
Check the fuse; replace if necessary.
Power failure.
Check the circuit of your power supply.
The ambient temperature is too low.
Try setting the chamber temperature to a colder
level to solve this problem.
It is normal that the refrigerator is not operating
during the automatic defrost cycle, or for a short
time after the appliance is switched on to protect
the compressor.
Odours from the compartments
The interior is dirty.
Clean the interior.
Some food, containers or wrapping cause odours.
The motor runs continuously
It is normal to frequently hear the sound of the
motor, it will need to run more when in following
circumstances:
Ø
Temperature setting is set colder than
necessary.
Ø
A large quantity of warm food has recently
been stored within the appliance.
Ø
The temperature outside the appliance is
too high.
Ø
Doors are kept open too long or too often.
Ø
After your installing the appliance or it has
been switched off for a long time.
A layer of frost occurs in the
compartment
Air outlets are blocked; insufficient ventilation;
door not fully closed.
Check that the air outlets are not blocked by
food and ensure food is placed within the appli
ance to allow sufficient ventilation. Ensure that
door is fully closed. To remove the frost:
~
chapter “Cleaning the appliance”
.
Temperature inside is too warm
You may have left the doors open too long or
too frequently; or the doors are kept open by
some obstacle; or the appliance is located with
insufficient clearance at the sides, back or top.
Do not open the doors unnecessarily or longer
than necessary; check clearance of appliance.
Doors can't be closed easily
Appliance is not tilted to the back about 15 mm.
Something inside is preventing the doors from
closing.
Check tilting and correct by turning the adjust
able feet, if necessary. Check interior and
remove obstacle.
The light is not working
LED light is automatically switched off due to the
door beeing kept open for too long.
LED light is damaged.
Close and reopen the door to reactivate the light.
Have the LED light be replaced
~
chapter “Light (LED)”
.