X-Cool Side by Side Refrigerator
523_58300000186266_ARA_EN_F
– 01.03.2018
Site 40 of 49
5.9
Noise
Cause
Troubleshooting
Fans
Fan vibration
Fan blade touches the housing
Fasten screws
Seal and check the fan (see 4.6, Sealing and checking the evaporator fan, page 24)
Compressor room
Compressor runs at high speed
Advise costumer
High frequency scream (until FD 06
Replace compressor without inverter (see 4.9, Removing the compressor, page 25)
Valve has no water connection and the
ice maker is
ON
Switch ice maker
OFF
, when there is no water connection
Doors
Frictional sound between door closer
and base hinge
Replace door closer (see 4.17, Exchanging the door closer base, page 30)
Drain outlet valve blocked
Replace drain outlet
Cooling Tube
Cooling
tubes
touch
each
other
(compressor room / evaporator)
Adjust cooling tubes
IWD
Ice flap touches plastic part
Ice production
Advise costumer
Advise costumer
Motor noise when Ice Maker switched
off.
Exchange control unit.
TCD Flap
Icing
Clean ice and seal flap(see 4.5, Sealing the TCD inlet flap, page 22) if necessary replace flap