X-Cool Side by Side Refrigerator
523_58300000186266_ARA_EN_F
– 01.03.2018
Site 14 of 49
3.2.1
Water flow for Dispenser
From the water valve (
④)
, the water flows into a water tank with a 1-
liter capacity (
⑥)
. The water is dispensed through the Dispenser (
③)
.
NOTE:
The freshness of the water may be reduced, if no water
has been dispensed for a longer time.
3.2.2
Water flow for Ice maker
From the water valve (
④)
, the water goes through water tubes in the
rear of the freezer and is then led to the ice maker water inlet. From
there it flows into the ice tray of the ice maker (
①)
.
3.3
Electronic control
This appliance is equipped with 5 NTC sensors, which control the
temperature of FC, RC, TCD, FC-evaporator and RC-evaporator
respectively.
3.3.1
FC/RC Running and temperature control
FC temperature range: -16 °C to -26 °C / 7 °F to -15 °F
RC temperature range: 2°C to 8°C / 35°C to 46°C
When the temperature of FC or RC rises, the control module connects
the solenoid valve (opens to FC evaporator or RC evaporator), FC-fan
or RC-fan, compressor, the FC or RC is under cooling. Once the
selected temperature is reached, the control module disconnects the
fan and also closes the solenoid valve.
RC/ FC
ON
: T
≥
Tse Toffset (2K) + Thysteresis (2.5 K)
OFF:
T
≤
Tse Toffset (2K) + Thysteresis (2.5 K)
NOTE:
When the relevant compartment door is open, the
compressor is still functioning but the relevant fan stops.