en
Installation instructions
18
WARNING ‒ Danger: Magnetism!
The removable profiles are magnetic and may
affect electronic implants, e.g. pacemakers or
insulin pumps.
▶
Persons with electronic implants must stay
at least 10 cm away from the magnetic pro-
files.
17.4 General information
Follow these general instructions during the installation.
¡
For the installation, observe the currently valid build-
ing regulations and the regulations of the local elec-
tricity and gas suppliers.
¡
When discharging the exhaust air, the official and
legal regulations, such as the regional building
code., must be observed.
¡
In order to freely access the fan box for servicing,
select an easy-to-reach installation site.
¡
The surfaces of the appliance are sensitive. Avoid
damaging them during installation.
17.5 Instructions for the electrical
connection
In order to safely connect the appliance to the elec-
trical system, follow these instructions.
WARNING ‒ Risk of electric shock!
It must always be possible to disconnect the appliance
from the electricity supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed.
▶
The mains plug for the mains power cable must be
easily accessible after the appliance is installed.
▶
If this is not possible, an all-pole isolating switch
must be integrated into the permanent electrical in-
stallation according to the conditions of overvoltage
category III and according to the installation regula-
tions.
▶
The permanent electrical installation must only be
wired by a professional electrician. We recommend
installing a residual-current circuit breaker (RCCB)
in the appliance's power supply circuit.
Sharp-edged components inside the appliance may
damage the connecting cable.
▶
Do not kink or trap the connecting cable.
¡
The connection data can be found on the rating
¡
The connecting cable is approx. 1.30 m long.
¡
This appliance complies with the EC interference
suppression regulations.
¡
The appliance corresponds to protection class 1.
You should therefore only use the appliance with a
protective earth connection.
¡
Do not connect the appliance to the power supply
during installation.
¡
Ensure that the protection against contact is guaran-
teed during installation.
17.6 Information on the installation situation
¡
Install this appliance in a worktop.
¡
The appliance is not suitable for combined opera-
tion with a gas hob.
¡
To install additional special accessory parts, ob-
serve the enclosed installation instructions.
¡
The width of the extractor hood must correspond at
least with the width of the hob.
¡
To optimally detect the cooking vapours, install the
appliance behind the hob.
To ensure that the appliance does not lose any power,
do not install any wall units above the appliance and
maintain the following clearances:
¡
At least 50 cm to the left and right from the appli-
ance to a wall or to an adjacent wall unit
¡
At least 5 cm from the frame of the appliance to a
wall
¡
At least 2 cm from the Guided Air suction area to a
unit wall
¡
Include a ventilation opening in the base with a
cross-section of 80 cm².