Operating Instructions

Operating modes

Exhaust-air mode:

The extractor-hood fan extracts the kit-
chen vapours and conveys them through
the grease filter into the atmosphere.

The grease filter absorbs the solid 
particles in the kitchen vapours.

The kitchen is kept almost free of grease
and odours.

D

When the extractor hood is operated

in exhaust-air mode simultaneously with
a different burner which also makes use
of the same chimney 

(such as gas, oil or

coal-fired heaters, continuous-flow heaters,
hot-water boilers) care must be taken to

ensure that there is an adequate supply
of fresh air 

which will be needed by the

burner for combustion.

Safe operation is possible provided that the
underpressure in the room where the
burner is installed does not exceed 4 Pa
(0.04 mbar).

Operating modes

This can be achieved if the combustion air
is able to flow through non-lockable 
openings, e.g. in doors, windows and in
conjunction with an air supply/air-intake wall
box or by other technical procedures such
as reciprocal interlocking.

If the air intake is inadequate, there is a
risk of poisoning from combustion gases
which are drawn back into the room.

An air-intake/exhaust-air wall box by itself is
no guarantee that the limiting value will not
be exceeded.

Note: When assessing the overall
requirement, the combined ventilation
system for the entire household must be
taken into consideration. This rule does not
apply to the use of cooking appliances,
such as hobs and ovens.

Lighting

Light / fan

switches

Filter grille

Chimney panelling

Glass panel

Summary of Contents for D99W45N0GB

Page 1: ...Installation instructions and how to use and look after your built in cooker hoods D99W5 NEFF UK Ltd ...

Page 2: ...2 Abb 1 GAZ Fig 1 ELECTRO ...

Page 3: ... is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar Operating modes This can be achieved if the combustion air is able to flow through non lockable openings e g in doors windows and in conjunction with an air supply air intake wall box or by other technical procedures such as reciprocal interlocking If the air intake is inadequate t...

Page 4: ... is situated over a gas hob operate the hood at maximum setting if three or more gas hotplates are operated simultaneously Safety instructions Do not flambé food directly under the extractor hood Risk of grease filter catching fire due to flames The hotplates must always be covered with a utensil Restrictions apply to the use of the extractor hood over a solid fuel burner coal wood etc See Install...

Page 5: ...off The displayed goes out shortly afterwards Intensive setting Maximum power is obtained at the intensive setting It is only required for short intervals Keep pressing the button until a ç appears in the display If the intensive setting is not cancelled by hand the fan will automatically switch back to step after 10 minutes Fan follow on Press the button The fan continues to run at step for 10 mi...

Page 6: ...l the bottom of the most outer filter until it comes away from the magnets 2 Unhook the filter in a vertical position from the top 4 Press the notch on the inner filter and fold the filter down Ausbauen der Fettfilter 3 Detach the safety cord behind the filter ...

Page 7: ...filter 1 Insert the inner filter at the back and fold the filter upwards Ausbauen der Fettfilter 3 Hook in the outer filter in a vertical position 4 Press the filter to the back until the magnets take hold 2 Attach the safety cord behind the filter ...

Page 8: ...n acoustic signal is sounded for 6 seconds after the fan has switched off and an appears in the display The grease filters should be cleaned straight away Filters and maintenance When cleaning the filters by hand soak them in hot soapy water first of all Do not use aggressive acidic or caustic cleaners Then brush the filters clean rinse them thoroughly and leave the water to drain off Cancel the i...

Page 9: ...ficiency Note Do not use alcohol spirit on plastic surfaces as dull marks may appear Caution Ensure that the kitchen is ade quately ventilated Avoid naked flames Clean the operating buttons with a mild soapy solution and a soft damp cloth only Do not use stainless steel cleaner to clean the operating buttons Stainless steel surfaces Use a mild non abrasive stainless steel cleaner Clean the surface...

Page 10: ...de the extractor hood after the filter frame has been detached The manufacturer of the extractor hoods accepts no liability for complaints which can be attributed to the design and layout of the pipework 1 Switch off the extractor hood and pull out the mains plug or switch off the electricity supply at the fuse box When switched on the halogen bulbs become very hot Even for some time after the bul...

Page 11: ... old appliance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment by disposing of packaging materials in an environmentally friendly manner Please ask your dealer or inquire at your local authority about current means of disposal The extractor hood can only ...

Page 12: ...bar This can be achieved if combustion air can flow through non lockable openings e g in doors windows and via the air intake exhaust air wall box or by other technical measures such as reciprocal interlocking etc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that th...

Page 13: ...be installed in the household circuit A suitable separator is a switch that has a contact gap of more than 3 mm and interrupts all poles Such devices include circuit breakers and contactors If the connecting cable for this appliance is damaged the cable must be replaced by the manufacturer or his cus tomer service or a similarly qualified person in order to prevent serious injury to the user Elect...

Page 14: ...of the hood at the centre of the location where the hood is going to be mounted 03 Use the template to mark the points on the wall where the screws will be moun ted In order to make it easier to hook the hood onto the screws draw the out line of the area where the hood will be attached Ensure that the minimum distance bet ween the hob and the extractor hood is maintained 550 mm for an electric hob...

Page 15: ...king the wall over the top edge of the lower section 12 Insert the whole chimney cover panel inclined and press back 13 Carefully pull the upper flue duct upwards and screw the sides to the fixing bracket with 2 screws 14 Fitting the glass panel 1 Hold the glass panel with both hands and carefully push it all the way to the bottom in the side guide rails In doing so do not scratch the printed area...

Page 16: ...9000 161 454 Printed in Germany 0306 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399 ...