12
en
Electrical connection
Electrical data:
Are to be found on the name plate inside the appli-
ance after removal of the filterframe.
Before undertaking any repairs,
always
disconnect the extractor hood from the electricity
supply.
Length of the connecting cable: 1.30 m.
This extractor hood corresponds to EC regulations
concerning RF interference suppression.
Installation
1. Draw a line on the wall from the ceiling to the
lower edge of the hood at the centre of the lo-
cation where the hood is going to be mounted.
2. Use the template or following the picture to
mark the points (
A-B-C
) on the wall where the
screws will be mounted.
Ensure that the minimum distance between the
hob and the extractor hood is maintained
460
mm
for the gas hob and electric hod
3. Drill ø 8 mm holes
A
and
B
for the extractor
hood. Drill ø 8 mm holes
C
for the chimney
brackets.
4. Insert plugs
11
into the holes
A
,
B
and
C
so that
they are flush with the wall.
5. Fix the brackets
7.2.1
using the screws sup-
plied.
6. Insert not totally the screw into the holes
A
.
Mounting the hood body
7. Before attaching the hood body, tighten the two
screws
Vr
located on the hood body mounting
points.
8. Hook the hood body onto the screws
12a
into
the holes
A
.
9. Fully tighten support screws
12a
.
10. Adjust screws
Vr
to level the hood body.
11. Tighten the safety screw
11
in holes
B
.
Installation
Note:
Take into account any special accessories
that are going to be fitted.
Remove charcoal filters, if present.
min. 460 Elektro
Gas*
20
595
232
135
A
A
B
C C
210
C C
433
���
��
Connection in Ducting Version
When installing the ducting version, connect the
hood to the chimney using either a flexible or rigid
pipe ø 150 or 120 mm, the choice of which is left to
the installer.
To install a ø 120 mm air exhaust connection,
insert the reducer flange
9
on the hood body
outlet.
Fix the pipe in position using sufficient pipe
clamps (not supplied).
�����
�
�����