background image

Imp

ort

Ap

plia

nce

s.c

om

THE EASIEST WAY TO SELF-IMPORT APPLIANCES DIRECT FROM EUROPE.

en

    Installation

20

5

Installation

Installation

Preparing the installation

Caution!

Ensure that there are no electrical wires, gas pipes or 

water pipes in the area where holes are to be drilled.

1.

Mark a vertical centre line on the wall from the 

ceiling to the lower edge of the extractor hood.

2.

Use the enclosed template to mark the positions for 

the screws and the outline of the attachment area.

3.

Drill five 8 mm diameter holes to a depth of 80 mm 

for fastening the appliance and press in the wall 

plugs flush with the wall. 

Installation

1.

Screw on the fixing bracket for the flue duct. 

¨

2.

Screw on brackets for the extractor hood hand-tight. 

Do not firmly tighten the screws. 

©

3.

Screw in the threaded bolt, leaving it protruding out 

of the wall by 

5–9 mm

ª

[

PP

PP

PP

PP

PP

[

$

[

%

NJONN

NBYNN

&

Summary of Contents for D96BMV5N5

Page 1: ...M EUROPE Thanks for choosing ImportAppliances for your kitchen appliance purchase We hope you are enjoying the convenience quality and affordability of your new appliance If you have any issues or que...

Page 2: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE en Instructions for installation and use EXTRACTOR HOOD...

Page 3: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE...

Page 4: ...g that the appliance works perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not le...

Page 5: ...cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s ent...

Page 6: ...fter sales service Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Risk of electric shock Penetrating moisture may result in an ele...

Page 7: ...disposal Dispose of packaging in an environmentally friendly manner Operating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flu...

Page 8: ...any fan setting except fan setting The function will remain active even after the fan is switched off Touch the Q symbol Switching off Touch the Q symbol AirFresh function Switching on Touch the 3 sym...

Page 9: ...n display If the metal grease filters or activated charcoal filter are is saturated the corresponding symbols will flash once the appliance has been switched off Metal grease filter Activated charcoal...

Page 10: ...ob Connecting directly Notes Before connecting the appliance reset all existing connections to the WiFi or other appliances If your extractor hood is connected directly to the hob it cannot be connect...

Page 11: ...our router If you do not have this follow the steps for Manually logging into your home network The extractor hood cannot be switched on during the connection process You can cancel the process at any...

Page 12: ...king that the remote diagnostics service is available in your country Note For more information and to check whether the remote diagnostics service is available in your country please visit the Help S...

Page 13: ...Cleaning products that dissolve limescale Aggressive all purpose cleaning products Oven spray Note Wash new sponge cloths thoroughly before use Note Follow all instructions and warnings included with...

Page 14: ...Clean the filters with a brush and then rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grea...

Page 15: ...found inside the appliance remove the metal mesh grease filter to gain access You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space bel...

Page 16: ...CleanAir recirculation mod ule cannot be regenerated Z5270X0 Z5170X1 Easy change filter for CleanAir recirculation mod ule can be regenerated Z50XXP0X0 CleanAir air recirculation module can be inte g...

Page 17: ...he installer is responsible for ensuring that the appliance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The wi...

Page 18: ...ir must therefore always be ensured An incoming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat...

Page 19: ...ning Risk of death Risk of poisoning from flue gases that are drawn back in The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate...

Page 20: ...regulations Warning Risk of electric shock It must always be possible to disconnect the appliance from the electricity supply The appliance must only be connected to a protective contact socket that...

Page 21: ...g to the lower edge of the extractor hood 2 Use the enclosed template to mark the positions for the screws and the outline of the attachment area 3 Drill five 8 mm diameter holes to a depth of 80 mm f...

Page 22: ...ttach the exhaust air pipe directly to the air pipe connector and seal Exhaust air pipe 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the r...

Page 23: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE 6...

Page 24: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE 6...

Page 25: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE 9001359245 9001359245 en...

Reviews: