NEFF D95FMV1N0 User Manual And Installation Instructions Download Page 16

en 

Installation instructions

16

Risk of poisoning from flue gases being
drawn back in.

If an extractor hood with an open-flued heat
production source is installed, the power
supply for the extractor hood must be
provided with a suitable safety switch.

Risk of poisoning from flue gases being
drawn back in.

Do not emit the exhaust air into a smoke or
exhaust gas flue that is in operation.

Do not emit the exhaust air into a shaft that
is used to ventilate installation rooms for
heat-producing appliances.

If the exhaust air is to be conveyed into a
smoke or exhaust gas flue, you must obtain
the consent of the heating engineer re-
sponsible.

WARNING ‒ Risk of suffocation!

Children may put packaging material over
their heads or wrap themselves up in it and
suffocate.

Keep packaging material away from chil-
dren.

Do not let children play with packaging ma-
terial.

WARNING ‒ Risk of fire!

Grease deposits in the grease filter may catch
fire.

The specified safety clearances must be
complied with in order to prevent a build-up
of heat.

Observe the specifications for your cooking
appliances. If the installation instructions for
the cooking appliances specify a different
clearance, the larger of the two must al-
ways be provided for. If gas hobs and elec-
tric hobs are operated together, the largest
specified clearance applies.

The appliance must be installed with no
more than one side directly next to a high-
sided unit or a wall. The distance between
the appliance and wall or high-sided unit
must be at least 50 mm.

Grease deposits in the grease filter may catch
fire.

Never work with naked flames close to the
appliance (e.g. flambéing).

Do not install the appliance near a heat-
producing appliance for solid fuel (e.g.
wood or coal) unless a closed, non-remov-
able cover is available. There must be no
flying sparks.

WARNING ‒ Risk of injury!

Components inside the appliance may have
sharp edges.

Wear protective gloves.

The appliance may fall down if it has not been
properly fastened in place.

All fastening components must be fixed
firmly and securely in place.

Risk of injury from glass splinters.

Protect the filter cover against impact.

Do not drop the filter cover.

Wear protective goggles during installation.

The appliance is heavy.

The appliance must not be fitted directly
onto plasterboard or similar lightweight ma-
terials.

To ensure correct installation, you must use
a material which is sufficiently stable and
suitable for both the structural conditions
and the weight of the appliance.

Changes to the electrical or mechanical as-
sembly are dangerous and may lead to mal-
functions.

Do not make any changes to the electrical
or mechanical assembly.

The filter cover may swing out.

Open the filter cover slowly.

Take hold of the filter cover after opening
until it no longer swings out.

Close the filter cover slowly.

Risk of injury when opening and closing the
hinges.

Keep your hands away from the hinges.

WARNING ‒ Risk of electric shock!

Sharp-edged components inside the appli-
ance may damage the connecting cable.

Do not kink or trap the connecting cable.

Summary of Contents for D95FMV1N0

Page 1: ...Extractor hood en User manual and installation instructions D95FMV1N0 D95FMW1N0 D96IMW1N0 D96IMV1N0 D96IKW1S0B D96IKW1S0...

Page 2: ...suring that the appliance works perfectly at its installation location Only use this appliance For extracting cooking vapour In private households and in enclosed spaces in a domestic environment Up t...

Page 3: ...ted operation is possible if the ap pliance is operated exclusively in circulat ing air mode WARNING Risk of fire Fatty deposits in the grease filters may catch fire Never operate the appliance withou...

Page 4: ...airs are dangerous Repairs to the appliance should only be carried out by trained specialist staff Only use genuine spare parts when repair ing the appliance If the power cord of this appliance is dam...

Page 5: ...the lighting if you no longer require it The lighting does not consume any energy Clean or replace the filters at regular intervals The effectiveness of the filter is retained Put the cooking lid on T...

Page 6: ...perating status Switching the appliance on or off Switching noise reduction on or off Switching the AirFresh function on or off Switching the fan run on on or off Decreasing the fan setting Increasing...

Page 7: ...and roasting fumes De pending on the setting of the sensor sensitivity the op timum fan setting is automatically switched on If the sensor control system reacts too weakly or too strongly the setting...

Page 8: ...t Please also follow the instructions in the Home Con nect app Notes Please note the safety precautions in this instruction manual and make sure that they are also observed when operating the applianc...

Page 9: ...the Home Connect app 8 Hob based hood control You can connect your appliance to a suitable hob and in this way control the functions of your appliance via the hob If both appliances are Home Connect c...

Page 10: ...rts e g grease filter on extractor hoods WARNING Risk of electric shock An ingress of moisture can cause an electric shock Before cleaning pull out the mains plug or switch off the fuse in the fuse bo...

Page 11: ...sh washer light discolouration may occur This discoloura tion has no effect on the performance of the metal grease filters Requirement The grease filters have been removed Removing the grease filter P...

Page 12: ...of old appliance Valuable raw materials can be reused by recycling 1 Unplug the appliance from the mains 2 Cut through the power cord 3 Dispose of the appliance in an environmentally friendly manner I...

Page 13: ...r set angled canopy hood Z51AII1X6 Clean Air Plus no flue cir culated air set angled canopy hood Z51AIV1X6 Clean Air Plus circulated air set external Z51AXC1N6 Clean Air Plus odour filter replacement...

Page 14: ...UA 5 GHz WLAN Wi Fi For indoor use only 15 Installation instructions Observe this information when installing the appliance 15 1 Scope of delivery After unpacking all parts check for any damage in tr...

Page 15: ...re falls below atmospheric pressure Toxic gases from the flue or the extraction shaft are sucked back into the living space Always ensure adequate fresh air in the room if the appliance is being opera...

Page 16: ...l The distance between the appliance and wall or high sided unit must be at least 50 mm Grease deposits in the grease filter may catch fire Never work with naked flames close to the appliance e g flam...

Page 17: ...s been correctly installed The mains plug for the mains power cable must be easily accessible after the appliance is installed If this is not possible an all pole isolating switch must be integrated i...

Page 18: ...nd the weight of the appliance 5 Check the cut out area for existing cables of other appliances Preparing the wall 1 Observe the information on the installation situation Page 17 2 Ensure that there a...

Page 19: ...re the exhaust pipe to the air pipe connector 2 Establish the connection to the exhaust air opening 3 Seal the joints Establishing the exhaust air connection exhaust pipe 120 mm diameter 1 Secure the...

Page 20: ...Wery Stra e 34 81739 M nchen GERMANY 9001641342 9001641342 010908 en Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Road Wolverton Mil...