background image

6

Removing and inserting the metal grease
filters:

Warning: 

The halogen bulbs must be 

switched off and cool.

1.

Press the catch on the grease filters
inwards and fold the filters down.

Filters and maintenance

2.

Clean the filters.

3.

Insert the clean filters back into the
hood.

Activated carbon filter:

For neutralizing odours in recirculating
mode.

Caution:

As the filter becomes more and more 
saturated with grease, there is an increased
risk of fire and the function of the extractor
hood may be impaired.

Important:

Change the activated carbon filter promptly
to prevent the risk of fire from the 
accumulation of heat when deep-fat frying
or roasting.

3.

Insert the metal grease filters.

Replacing the activated carbon filter:

During normal operation (1 to 2 hours per
day) the activated carbon filters should
be replaced approximately 1 x year.

A replacement filter can be obtained
from any authorized dealer (see optional 
accessories).

Use original filters only.

By doing so you will obtain maximum
performance from your extractor hood.

Disposing of the old activated carbon 
filter:

There are no pollutants in the activated
carbon filters. They can therefore be 
disposed of as part of your normal
domestic refuse.

3.

Engage the catches at both sides.

4.

Insert the metal grease filters (see
"Removing and inserting the metal 
grease filters").

Removing the filter:

Warning: 

The halogen bulbs must be 

switched off and cool.

1.

Remove the metal filters.

2.

Press the catches at both sides of the 
filter inwards and lift the carbon filter
down and out.

Inserting the filter:
Warning: 

The halogen bulbs must be 

switched off and cool.

1.

Remove the metal-mesh filters
(see "Removing and inserting the metal-
mesh grease filters").

2.

Insert the activated carbon filter.

Summary of Contents for D91M5

Page 1: ...Installation instructions and how to use and look after your built in cooker hoods D91M5 NEFF UK Ltd...

Page 2: ...2 Abb 1 ELECTRO Fig 1 GAZ...

Page 3: ...stion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the overall requirement the...

Page 4: ...to ensure they do not play with the appliance If the connecting cable for this appliance is damaged the cable must be replaced by the manufacturer or his customer service or a similarly qualified per...

Page 5: ...more and more saturated with grease not only does the risk of it catching fire increase but the efficiency of the extractor hood can also be adversely affected Important By cleaning the metal grease...

Page 6: ...the activated carbon filters should be replaced approximately 1 x year A replacement filter can be obtained from any authorized dealer see optional accessories Use original filters only By doing so y...

Page 7: ...aces Use a mild non abrasive stainless steel cleaner Clean the surface in the same direction as it has been ground and polished Do not use any of the following to clean stainless steel surfaces abrasi...

Page 8: ...iance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment b...

Page 9: ...air which will be needed by the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be a...

Page 10: ...There should be no sharp bends l 120 mm approx 113 cm2 l 150 mm approx 177 cm2 If pipes have different diameters Insert sealing strip For exhaust air mode ensure that there is an adequate supply of f...

Page 11: ...an earthed socket that has been installed according to relevant regulations If possible site the earthed socket directly above the chimney panelling in the ceiling Electrical data Are to be found on...

Page 12: ...gas hotplates 1 Mark the centre point of the extractor hood on the ceiling 2 Using the template mark screw positions on the ceiling 3 Drill 4x 8 mm holes and insert wall plugs flush with the ceiling 4...

Page 13: ...the support frame at the specified overall height with 8 screws 10 Align the extractor hood To do this loosen the ceiling screws in the support frame 09 Screw the extractor hood to the support frame a...

Page 14: ...ve foil 15 Push up the upper flue section and screw into position 16 Insert the two sections of the lower flue and clip together Protect the extractor hood from damage 14 Place the two sections of the...

Page 15: ...15 Accessories 351210 Z5120X5...

Page 16: ...9000 032 329 Printed in Germany 0105 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399...

Reviews: