background image

7

Operating procedure

Switching off

With fan run-on started from manual
mode:

Press the            button.

The fan runs at the setting last selected.

The dot on the display flashes.

After 10 minutes the fan switches off and
the displays go out.

With fan run-on started from automatic
mode:

Press the            button.

Fan run-on does not start until the 
automatic function has switched the fan
back to Setting 

|

.

The dot on the display flashes.

After 10 minutes the fan switches off and
the displays go out.

Without fan run-on:

Press the 

L

button.

Light

The light can be used at any time, even
when the appliance has been switched
off.

Switching on/off:

Press the 

a

button.

Special functions

Adjusting the sensitivity of the sensor
control:

1.

Press and 

hold down

the automatic

button

.

2.

To display the current sensitivity, press
the 

+

or 

button.

3.

You can now change the sensitivity of
the sensor control by pressing the 

+

or

button.

Factory setting:

@

.

Lowest setting:

{

.

Highest setting:

Ö

.

Switching on the light automatically, e.g.
via a timer:

Fan and light must be switched off.

Switching on:

Simultaneously

press the 

a

and 

L

buttons.

After approx. 3 seconds the light 
switches on to acknowledge the setting.

Switching off:

Repeat the process with the light switched
on.

After approx. 3 seconds the light 
switches off to acknowledge the setting.

Summary of Contents for D8985

Page 1: ...How to use and look after your built in cooker hoods D8985 NEFF UK Ltd...

Page 2: ...2 mind 650 mind 550 Abb 1 ELECTR Fig 1 GAZ...

Page 3: ...ng etc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limit...

Page 4: ...ore using your new appliance please read these Instructions for Use carefully They contain important information concerning your personal safety as well as on use and care of the appliance Please keep...

Page 5: ...ncrease the fan settings or switch on the intensive setting press the button The intensive setting operates at maximum power which should be used only briefly If the intensive setting is not switched...

Page 6: ...f manually the fan automatically switches back to the optimum fan setting after 10 minutes 2 To switch off the intensive setting press the button Automatic mode has been switched on again Switching ov...

Page 7: ...at any time even when the appliance has been switched off Switching on off Press the a button Special functions Adjusting the sensitivity of the sensor control 1 Press and hold down the automatic but...

Page 8: ...nds after the fan has switched off and an appears in the display The grease filters should be cleaned straight away Cleaning the metal grease filters The filters can be cleaned in a dishwasher It is h...

Page 9: ...metal grease filters see Removing and inserting the metal grease filters 5 Cancel the in the display Press the L button for at least 3 seconds The is cancelled 3 Insert the metal grease filters Repla...

Page 10: ...faces Use a mild non abrasive stainless steel cleaner Clean the surface in the same direction as it has been ground and polished Do not use any of the following to clean stainless steel surfaces abras...

Page 11: ...d Disconnect the extractor hood from the mains electricity supply by pulling out the plug or switching it off at the main fuse box Wait for approx 1 minute and then switch it on again If you have any...

Page 12: ...m will cause condensation to form on the hood Old appliances are not worthless rubbish If they are disposed of in an environment friendly manner valuable raw materials can be recovered for use again B...

Page 13: ...mbustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be achieved if combustion air can flow through non...

Page 14: ...hat equates to that of round pipes There should be no sharp bends l 120 mm approx 113 cm2 l 150 mm approx 177 cm2 If pipes have different diameters Insert sealing strip For exhaust air mode ensure tha...

Page 15: ...ly be connected to the electricity supply by a properly qualified electrician A separator must be installed in the household circuit A suitable separator is a switch that has a contact gap of more tha...

Page 16: ...emove the grease filter refer to Operating Instructions 2 Draw a line on the wall from the ceiling to the lower edge of the hood at the centre of the location where the hood is going to be mounted 3 U...

Page 17: ...ning in the extractor hood Protect the cover panels from scratches for example by laying the template used for marking the wall over the top edge of the lower section 10 Connect up the air outlet pipe...

Page 18: ...18 Notes...

Page 19: ...19 Notes...

Page 20: ...20 Notes...

Page 21: ...21 Notes...

Page 22: ...22 Notes...

Page 23: ...23 Z5114X5 Z5844X0 Z5841N0 Z5861N0 264765 1 2 3 4 5 6 2x 10x 2x 351210...

Page 24: ...5750 205 663 Printed in Germany 0703 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399...

Reviews: