15

Electrical connection

Prior to installation

WARNING: THIS APPLIANCE MUST BE
EARTHED
IMPORTANT: Fitting a Different Plug:

The wires in the mains lead are coloured in
accordance with the following code:

Green and Yellow

– Earth

Blue

– Neutral

Brown

– Live

If you fit your own plug, the colours of
these wires may not correspond with the
identifying marks on the plug terminals.
This is what you have to do:

1.

Connect the green and yellow (Earth)
wire to the terminal in the plug marked
‘E’ or with the symbol (        ), or 
coloured green or green and yellow.

2.

Connect the blue (Neutral) wire to the
terminal in the plug marked ‘N’ or 
coloured black.

3.

Connect the brown (Live) wire to the 
terminal marked ‘L’, or coloured red.

The extractor hood 

should only be

connected to an earthed socket that has
been installed according to relevant
regulations.
If possible, site the earthed socket directly
behind the chimney panelling.

Electrical data:

Are to be found on the name plate inside
the appliance after removal of the filter
frame.

Before undertaking any repairs,

always disconnect the extractor hood from
the electricity supply.

Length of the connecting cable: 1.30 m.
If it is necessary to wire the extractor
hood directly into the mains:

The extractor hood should only be
connected to the electricity supply by a
properly qualified electrician.
A separator must be installed in the
household circuit. A suitable separator is a
switch that has a contact gap of more than
3 mm and interrupts all poles. Such
devices include circuit breakers and
contactors.
This extractor hood corresponds to EC
regulations concerning RF interference
suppression.

Exhaust air

Recircula-

ting air

20,2

60 cm

22,4

23,2

25,4

90 cm

We reserve the right to construction changes within the 
context of technical development.

Preparing the wall

The wall must be flat and perpendicular.

Ensure that the wall is capable of
providing a firm hold for mounting
screws and plugs.

Appliances with a rear light:

A recess panel or tiles fitted to the wall
directly under the extractor hood must
not project by more than 15 mm, 
otherwise the light cover may be 
damaged.

Weight in kg:

Changing over from exhaust-
air to recirculating mode

Changing the electronic control system
to recirculating mode:

The standard factory setting is for
operation in exhaust-air mode.

To change the mode, the extractor hood
must have been connected up and
should be switched off.

1.

Press and hold down the 

L

button.

2.

Press the            button for approx. 
3 seconds.

ã

is displayed.

3.

Release the buttons.

The display goes out shortly 
afterwards.

Resetting to exhaust-air mode:

1.

Repeat the procedure.

#

is displayed.

2.

Release the buttons.

The display goes out shortly 
afterwards.

Summary of Contents for D8985

Page 1: ...How to use and look after your built in cooker hoods D8985 NEFF UK Ltd...

Page 2: ...2 mind 650 mind 550 Abb 1 ELECTR Fig 1 GAZ...

Page 3: ...ng etc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limit...

Page 4: ...ore using your new appliance please read these Instructions for Use carefully They contain important information concerning your personal safety as well as on use and care of the appliance Please keep...

Page 5: ...ncrease the fan settings or switch on the intensive setting press the button The intensive setting operates at maximum power which should be used only briefly If the intensive setting is not switched...

Page 6: ...f manually the fan automatically switches back to the optimum fan setting after 10 minutes 2 To switch off the intensive setting press the button Automatic mode has been switched on again Switching ov...

Page 7: ...at any time even when the appliance has been switched off Switching on off Press the a button Special functions Adjusting the sensitivity of the sensor control 1 Press and hold down the automatic but...

Page 8: ...nds after the fan has switched off and an appears in the display The grease filters should be cleaned straight away Cleaning the metal grease filters The filters can be cleaned in a dishwasher It is h...

Page 9: ...metal grease filters see Removing and inserting the metal grease filters 5 Cancel the in the display Press the L button for at least 3 seconds The is cancelled 3 Insert the metal grease filters Repla...

Page 10: ...faces Use a mild non abrasive stainless steel cleaner Clean the surface in the same direction as it has been ground and polished Do not use any of the following to clean stainless steel surfaces abras...

Page 11: ...d Disconnect the extractor hood from the mains electricity supply by pulling out the plug or switching it off at the main fuse box Wait for approx 1 minute and then switch it on again If you have any...

Page 12: ...m will cause condensation to form on the hood Old appliances are not worthless rubbish If they are disposed of in an environment friendly manner valuable raw materials can be recovered for use again B...

Page 13: ...mbustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be achieved if combustion air can flow through non...

Page 14: ...hat equates to that of round pipes There should be no sharp bends l 120 mm approx 113 cm2 l 150 mm approx 177 cm2 If pipes have different diameters Insert sealing strip For exhaust air mode ensure tha...

Page 15: ...ly be connected to the electricity supply by a properly qualified electrician A separator must be installed in the household circuit A suitable separator is a switch that has a contact gap of more tha...

Page 16: ...emove the grease filter refer to Operating Instructions 2 Draw a line on the wall from the ceiling to the lower edge of the hood at the centre of the location where the hood is going to be mounted 3 U...

Page 17: ...ning in the extractor hood Protect the cover panels from scratches for example by laying the template used for marking the wall over the top edge of the lower section 10 Connect up the air outlet pipe...

Page 18: ...18 Notes...

Page 19: ...19 Notes...

Page 20: ...20 Notes...

Page 21: ...21 Notes...

Page 22: ...22 Notes...

Page 23: ...23 Z5114X5 Z5844X0 Z5841N0 Z5861N0 264765 1 2 3 4 5 6 2x 10x 2x 351210...

Page 24: ...5750 205 663 Printed in Germany 0703 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399...

Reviews: