  Cleaning and maintenance   

en

7

Saturation display

When the metal mesh grease filters or the activated 

carbon filter are saturated, a signal sounds for approx. 

4 seconds after the fan is switched off. In addition, this 

symbol is indicated on the display: 

ª

If you have not yet done so, the metal mesh grease 

filters should be cleaned now. 
For instructions on how to clean the metal mesh grease 

filters, please refer to the section 

Cleaning and 

maintenance

.

While the saturation display is flashing, it can be reset. 

To do this, press the – button.

Audible signal 

Switching on the acoustic signal

When the fan is switched off, press the 

#

 and + at the 

same time for approx. three seconds. An 

acknowledgement signal sounds.

Switching off the acoustic signal

Repeat the "Switching on the acoustic signal" process.

2

Cleaning and maintenance

Cleaning 

and maint

enance

:

Warning

Risk of burns!

The appliance will become hot during operation, 

especially near the bulbs. Allow the appliance to cool 

down before cleaning.

:

Warning

Risk of electric shock!

Penetrating moisture may result in an electric shock. 

Clean the appliance using a damp cloth only. Before 

cleaning, pull out the mains plug or switch off the circuit 

breaker in the fuse box.

:

Warning

Risk of electric shock!

Do not use any high-pressure cleaners or steam 

cleaners, which can result in an electric shock.

:

Warning

Risk of injury!

Components inside the appliance may have sharp 

edges. Wear protective gloves.

Cleaning agents

Observe the information in the table to ensure that the 

different surfaces are not damaged by using the wrong 

type of cleaning agent. Do not use

harsh or abrasive cleaning agents,

cleaning agents with a high concentration of alcohol,

hard scouring pads or sponges,

high-pressure cleaners or steam cleaners.

Wash new sponge cloths thoroughly before use.
Follow all instructions and warnings included with the 

cleaning agents.

Area

Cleaning agents

Stainless steel

Hot soapy water: 

Clean with a dish cloth and dry with a soft 

cloth.
Clean stainless steel surfaces in the direction 

of the grain only.
Special stainless steel cleaning products are 

available from our after-sales service or from 

specialist retailers. Apply a very thin layer of 

the cleaning product with a soft cloth.

Painted surfaces

Hot soapy water: 

Clean using a damp dish cloth and dry with a 

soft cloth/towel.
Do not use any stainless steel cleaners.

Aluminium and plastic Glass cleaner: 

Clean with a soft cloth.

Glass

Glass cleaner: 

Clean with a soft cloth. Do not use a glass 

scraper.

Operating controls

Hot soapy water: 

Clean using a damp dish cloth and dry with a 

soft cloth.
Risk of damage to the electronics from pene-

trating moisture. Never clean operator con-

trols with a wet cloth.
Do not use any stainless steel cleaners.

Summary of Contents for D86EH52N0B/02

Page 1: ...en Instructions for installation and use Extractor hood...

Page 2: ...pliance works perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appli...

Page 3: ...oming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitab...

Page 4: ...les replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales s...

Page 5: ...itch it off again several minutes after you have finished cooking This is the most effective way of removing the kitchen fumes Control panel model 1 Control panel Setting the fan Switching on the appl...

Page 6: ...at setting Press the or button to change the fan strength Switching off Press the button Intensive setting You can use the intensive setting if there is a large build up of odours and fumes vapours P...

Page 7: ...cleaners or steam cleaners which can result in an electric shock Warning Risk of injury Components inside the appliance may have sharp edges Wear protective gloves Cleaning agents Observe the informat...

Page 8: ...her The metal mesh grease filters must not be wedged in By hand Note You can use a special grease solvent for stubborn dirt It can be ordered via the Online Shop Soak the metal mesh grease filters in...

Page 9: ...en inserting halogen bulbs do not touch the glass tube Use a clean cloth to insert the halogen bulbs 1 Carefully remove the bulb ring using a suitable tool 2 Pull out the bulb and replace it with a bu...

Page 10: ...ir is carried out by trained service technicians who carry original spare parts for your appliances Accessories for circulating air mode not included in the delivery Notes Follow the installation inst...

Page 11: ...uctions The installer is responsible for ensuring that the appliance works perfectly at its installation location The width of the extractor hood must correspond at least with the width of the hob For...

Page 12: ...responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour ex...

Page 13: ...rformance is not achieved and fan noise is increased The pipes or hoses for laying the exhaust air line must consist of non combustible material Round pipes An inner diameter of 150 mm but at least 12...

Page 14: ...extractor hood 2 Mark positions for the screws and the contour of the attachment area 3 Drill five 8 mm diameter holes to a depth of 80 mm for the attachments and press in the wall plugs flush with t...

Page 15: ...connector and seal Exhaust air pipe 120 mm 1 Attach the reducing connector directly to the air pipe connector 2 Attach the exhaust air pipe to the reducing connector 3 Seal both joints appropriately A...

Page 16: ...www neff international com 9001028149 9001028149 941103 Constructa Neff Vertriebs GmbH Carl Wery Stra e 34 D 81739 M nchen Register your product online...

Reviews: