Operating modes    

en

5

Ç

Operating modes

Operating modes

Exhaust air mode

Note: 

The exhaust air must not be conveyed into a 

functioning smoke or exhaust gas flue or into a shaft 

which is used to ventilate installation rooms which 

contain heat-producing appliances.

Before conveying the exhaust air into a non-

functioning smoke or exhaust gas flue, obtain the 

consent of the heating engineer responsible.

If the exhaust air is conveyed through the outer wall, 

a telescopic wall box should be used.

Air recirculation

Note: 

To bind odours in air recirculation mode, you 

must install an activated carbon filter. The different 

options for operating the appliance in air recirculation 

mode can be found in the brochure. Alternatively, ask 

your dealer. The required accessories are available 

from specialist retailers, from customer service or from 

the Online Shop.

1

Operating the appliance

Operating the appliance

These instructions apply to several appliance variants. 

It is possible that individual features are described 

which do not apply to your appliance.

Note: 

Switch on the extractor hood when you start 

cooking and switch it off again several minutes after you 

have finished cooking. This is the most effective way of 

removing the kitchen fumes.

Control panel

Setting the fan

Switching on

Slide the switch to the required fan setting.

Switching off

Slide the switch to the zero setting.

Intensive setting

You can use the intensive setting if there is a large 

build-up of odours and fumes/vapours.
Slide the switch to 

˜

.

Intensive mode is now activated.

Lighting

The lighting can be switched on and off independently 

of the ventilation.
Press the 

A

 button.

The air which is drawn in is cleaned 

by the grease filters and conveyed to 

the exterior by a pipe system.

The air which is drawn in is cleaned by 

the grease filters and an activated 

carbon filter, and is conveyed back into 

the kitchen.

Explanation

<

Light on/off

1-3

Fan settings

P

Intensive mode

3



Summary of Contents for D5655X1

Page 1: ...M EUROPE Thanks for choosing ImportAppliances for your kitchen appliance purchase We hope you are enjoying the convenience quality and affordability of your new appliance If you have any issues or que...

Page 2: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE en Instructions for installation and use EXTRACTOR HOOD...

Page 3: ...works perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance un...

Page 4: ...xes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures t...

Page 5: ...the direction of the grain only Do not use any stainless steel cleaners for operator controls Surface damage due to strong or abrasive cleaning agents Never use strong and abrasive cleaning agents Ri...

Page 6: ...from the Online Shop 1Operating the appliance OperatingtheapplianceThese instructions apply to several appliance variants It is possible that individual features are described which do not apply to y...

Page 7: ...gents Cleaning agents with a high alcohol content Hard scouring pads or cleaning sponges High pressure cleaners or steam cleaners Wash new sponge cloths thoroughly before use Follow all instructions a...

Page 8: ...mesh grease filters in the appliance using a damp cloth The metal mesh grease filters can be cleaned in the dishwasher or by hand By hand Note You can use a special grease solvent for stubborn dirt I...

Page 9: ...rease filter 2 Insert the screw through the wing nut and the sleeve Screw it into the centre of the intermediate floor Note The screw wing nut and sleeve are included with the activated charcoal filte...

Page 10: ...nce and the telephone number of the after sales service in the space below to save time should it be required Please be aware that a visit by an after sales engineer will be charged if a problem turns...

Page 11: ...that individual features are described which do not apply to your appliance This appliance is installed in chimneys or chimney hoods Follow the enclosed installation instructions for additional specia...

Page 12: ...air mode at the same time as room air dependent heat producing appliance is being operated Room air dependent heat producing appliances e g gas oil wood or coal operated heaters continuous flow heater...

Page 13: ...ions of overvoltage category III and according to the installation regulations The permanent electrical installation must only be wired by a professional electrician We recommend installing a residual...

Page 14: ...age category III and according to the installation regulations The permanent electrical installation must only be wired by a professional electrician We recommend installing a residual current circuit...

Page 15: ...r air outlet If the dust extractor hood has a rectangular air outlet the air inlet provided must be screwed in tightly via the air outlet 5Installation InstallationFinal fitting stage 1 Remove the met...

Page 16: ...IRECT FROM EUROPE Installation en 15 Removing the appliance 1 Disconnect the electrical connection 2 Undo the screws 3 Disconnect the pipes 4 Hold the extractor hood down Pull at the front and rear of...

Page 17: ...ImportAppliances com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE 9001396523 9001396523 980801 en...

Reviews: