background image

7

Cleaning the metal mesh grease filters

These instructions apply to several appliance variants. It is 

possible that individual features are described which do not 

apply to your appliance.

Risk of fire!

Grease deposits in the grease filter may catch fire.

Clean the grease filter at least every 2 months. 

Never operate the appliance without the grease filter.

Notes

Do not use any aggressive, acidic or alkaline cleaning 

agents.

When cleaning the metal mesh grease filters, also clean the 

holder for the metal mesh grease filters in the appliance 

using a damp cloth.

The metal mesh grease filters can be cleaned in the 

dishwasher or by hand.

In the dishwasher:
Note: 

If the metal mesh grease filters are cleaned in the 

dishwasher, slight discolouration may occur. This has no effect 

on the function of the metal mesh grease filters.

Do not clean heavily soiled metal mesh grease filters together 

with utensils.

Place the metal mesh grease filters loosely in the dishwasher. 

The metal mesh grease filters must not be wedged in.

By hand:
Note: 

You can use a special grease solvent for stubborn dirt. It 

can be ordered via the Online Shop.

Soak the metal mesh grease filters in a hot soapy solution. 

Clean the filters with a brush and then rinse them thoroughly.

Leave the metal mesh grease filters to drain.

Removing metal grease filter

1.

Push the lock and then push the metal grease filter back and 

pull it down.
While doing this, place your other hand under the metal 

grease filter.

Note: 

To avoid causing damage, do not bend the metal 

grease filter.

2.

Take the metal grease filter out of the holder.

Note: 

Grease may accumulate in the bottom of the metal 

grease filter. Hold the metal grease filter level to prevent 

grease from dripping out.

3.

After removing the metal grease filters, clean the inside of the 

appliance.

4.

Clean the metal grease filters and let them dry before re-

fitting them.

Installing the metal mesh grease filter

1.

Insert the metal mesh grease filter.
While doing this, place the other hand under the metal mesh 

grease filter.

2.

Fold the metal mesh grease filter upwards, locking it in place.

Changing the activated charcoal filter (only in 

circulating-air mode)

In order to guarantee efficient odour filtration, the filter must be 

serviced regularly.
The activated charcoal filters must be replaced at least every 

4 months.

Notes

The activated charcoal filters are not included in the delivery. 

The activated charcoal filters can be obtained from specialist 

retailers, from our after-sales service or from the Online Shop.

The activated charcoal filters cannot be cleaned or 

reactivated.

Note: 

Only use genuine replacement filters. This ensures 

optimal performance of the appliance.

1.

Remove the metal grease filter, see the chapter 

Removing 

the metal grease filter

.

2.

Undo the threaded joint on the activated charcoal filter cover.

3.

Remove the activated charcoal filter.

4.

Insert the activated charcoal filter.

5.

Screw the cover in place.

6.

Install the metal grease filter, see the chapter 

Installing the 

metal grease filter

.

Summary of Contents for D16EB12B0

Page 1: ...en Instruction manual Extractor hood D16EB12B0 D16EB12N0 D16EB12W0...

Page 2: ......

Page 3: ...used by children over the age of 8 years old and by persons with reduced physical sensory or mental capabilities or by persons with a lack of experience or knowledge if they are supervised or are inst...

Page 4: ...nce e g flamb ing Do not install the appliance near a heat producing appliance for solid fuel e g wood or coal unless a closed non removable cover is available There must be no flying sparks Risk of f...

Page 5: ...pack the appliance and dispose of the packaging in an environmentally responsible manner Environmentally friendly disposal Dispose of packaging in an environmentally friendly manner Operating modes Th...

Page 6: ...which can result in an electric shock Risk of injury Components inside the appliance may have sharp edges Wear protective gloves Cleaning agents Observe the information in the table to ensure that th...

Page 7: ...ing this place your other hand under the metal grease filter Note To avoid causing damage do not bend the metal grease filter 2 Take the metal grease filter out of the holder Note Grease may accumulat...

Page 8: ...pliance remove the metal mesh grease filter to gain access You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time shou...

Page 9: ...9 Accessories for circulated air mode not included in the delivery Activated charcoal filter Z5101X0...

Page 10: ......

Page 11: ......

Page 12: ...www neff international com Register your product online 9001012907 9001012907 940626 Constructa Neff Vertriebs GmbH Carl Wery Stra e 34 D 81739 M nchen...

Reviews: