Prior to installation
For optimum extractor hood efficiency:
❑
Short, smooth air exhaust pipe.
❑
As few bends in the pipe as possible.
❑
Diameter of pipe to be as large as
possible and no tight bends in pipe.
If long, rough exhaust-air pipes,
many pipe bends or smaller pipe
diameters are used, the air extraction
rate will no longer be at an optimum
level and there will be an increase in
noise.
❑
Round pipes:
We recommend
Internal diameter:
150 mm
(at least
120 mm).
❑
Flat ducts
must have an internal cross-
section that equates to that of round
pipes.
There should be no sharp bends.
l
120 mm approx. 113 cm
2
l
150 mm approx. 177 cm
2
❑
If pipes have different diameters:
Insert sealing strip.
❑
For exhaust-air mode,
ensure that
there is an adequate supply of fresh air.
Circulating-air mode
❑
With activated carbon filter if exhaust-air
mode is not possible.
Connecting a
l
150 mm exhaust-air
pipe:
❑
Mount the pipe directly onto the air
outlet on the hood.
Connecting a
l
120 mm exhaust-air
pipe:
❑
Attach the reducing connector directly to
the air pipe.
The complete
installation set can be
obtained
from
specialist
outlets.
The corresponding
accessory numbers
can be found at the
end of these operating
instructions.
❑
Attach the exhaust-air pipe to the
reducing connector.
280
260
min.140
775-1179
40
min.
600
500
600/900
Summary of Contents for D 96M2 Series
Page 69: ...69 D 4 Pa 0 04 mbar...
Page 70: ...70 FD T E 15 A...
Page 71: ...1 2 8 10 0 10 Off 0 71...
Page 72: ...72 2 3 1 3 A 1 2 3 1 2 1 2 1...
Page 73: ...73 3 12 Volt 20 Watt G4 4 5 1 2...
Page 74: ...74 TRGI 50 mm 650 mm 1 550 mm 1...
Page 77: ...77 kg 20 0 19 5 60 cm 22 5 22 0 90 cm 1 30 m 3 mm LS...
Page 78: ...78 1 2 3 550 mm 650 mm 4 4 2 8 mm 6 5 2 2 30 172 476 36 5 400 min 550 Elektro min 650 Gas 216...
Page 79: ...8 9 12 2 1 2 3 13 10 11 7 79...