background image

Warning

This equipment should be operated only from the included power supply. To 
remove power from the equipment safely, remove all power cords from the 
rear of the equipment, or the desktop power module (if detachable), or from 
the power source receptacle (wall plug).
Power cords should be routed so that they are not likely to be stepped on or 
pinched by items placed upon or against them.
Do not defeat the safety purpose of a polarized or grounding-type plug. 
A polarized plug has two blades with one wider than the other. A ground-
ing-type plug has two blades and a third grounding prong. The wide blade 
or the third prong is provided for your safety. If the provided plug does not 
fit into your outlet, consult an electrician for replacement of the obsolete 
outlet. Unplug this apparatus during lightning storms or when unused for 
long periods of time.
Refer all servicing to qualified service personnel. There are no user-service-
able parts inside. To prevent the risk of shock, do not attempt to service this 
equipment yourself because opening or removing covers may expose you to
dangerous voltage or other hazards. Contact your local Neets reseller or 
distributor.
If the equipment has slots or holes in the enclosure, these are provided to 
prevent overheating of sensitive components inside. These openings must 
never be blocked by other objects.
Do not use this equipment near water.
To reduce the risk of fire or electric shock, do not expose this apparatus to 
rain or moisture and objects filled with liquids.
Unplug the product before cleaning. Clean only with a dry cloth and not 
cleaning fluid or aerosols. Such products
could enter the unit and cause damage, fire, or electric shock. Some 
substances may also mar the finish of the product.

Caution

Read these instructions. Read and understand all safety and operating 
instructions before using the equipment. Keep these Instructions.
The safety instructions should be kept for future reference. Heed all warn-
ings. Follow all warnings and instructions marked on the equipment or in 
the user information. Avoid attachments. Do not use tools or attachments 
that are not recommended, as they may be hazardous.

FCC Class A Notice

This equipment has been tested and found to comply with the limits for a Class 
A digital device, pursuant to part 15 of the FCC Rules. Operation is subject to 
the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference 
that may cause undesired operation.
The Class A limits are designed to provide reasonable protection against harm-
ful interference when the equipment is operated in a commercial environment. 
This equipment generates, uses, and can radiate radio frequency energy and, 
if not installed and used in accordance with the instruction manual, may cause 
harmful interference to radio communications. Operation of this equipment in 
a residential area is likely to cause harmful interference, in which case the user 
will be required to correct the interference at his own expense.
FCC regulations state that any unauthorized changes or modifications to this 
equipment, not expressly approved by the manufacturer, could void the user’s 
authority to operate this equipment.

14

Summary of Contents for UniForm

Page 1: ...Installation guide Neets Control UniForm...

Page 2: ...Thank you Thank you for including the Neets Control UniForm as part of your user experience strategy For specifications go to www neets dk uniform...

Page 3: ...Included in the box 2...

Page 4: ...Front of controller Buttons 3 1 76 mm 1 94 mm Mini USB Port E paper Display Buttons...

Page 5: ...Back of controller Magnets LAN PoE Magnet Magnet Terminals 4 GND I O 1 I O 2 I O 3 RX 1 TX 1 GND TX 2 TX 3 GND...

Page 6: ...145 cm 57 The controller is designed to be mounted onto a wall in a vertical orientation We recommend locating the center of the controller between 145 cm 165 cm 57 65 above the floor depending on th...

Page 7: ...ounting onto either a 1 gang electrical box based on EU standards or a DK 1 5M LK FUGA Air only It can also be mounted directly onto the wall without any electrical box When using EU or DK electrical...

Page 8: ...sure the wall itself is even to prevent any distortion of the bracket 3 Mounting the bracket 5 4 3 2 1 7 Mount the bracket onto the electrical box using the dedicated screws for the type of electrica...

Page 9: ...8 Mounting onto a DK 1 5M electrical box LK FUGA Air...

Page 10: ...Mounting onto an EU 1 gang electrical box 9...

Page 11: ...Mounting directly onto the wall Cutout in the wall must be at least 45 x 45 mm 1 8 x 1 8 10...

Page 12: ...Connect the PoE cable and terminal connectors if they are a part of the installation from the wall to the controller Powering the Controller 4 From IEEE802 3 compliant PoE injector or switch 11...

Page 13: ...lined up correctly and ensure that the alignment holes are free so that all four magnets are able to connect To remove the controller use both hands to grasp the controller on each side and pull it st...

Page 14: ...a USB cable Now using the Neets Project Designer software you can upload a projectfile directly to the controller For more information about Neets Project Designer visit www neets dk product neets pr...

Page 15: ...product before cleaning Clean only with a dry cloth and not cleaning fluid or aerosols Such products could enter the unit and cause damage fire or electric shock Some substances may also mar the fini...

Page 16: ...ets A S Langballe 4 8700 Horsens Denmark 45 75 666 099 sales neets dk www neets dk Learn more at neets dk Visit our website neets dk for additional information about the product and the latest firmwar...

Reviews: