background image

Page 2 of 12

Foreword

Neets EasyConnect solves one of the most common and frustrating problems encountered in AV presentations. 

When a guest presenter wants to connect a laptop computer, all too often the proper cables cannot be found, or 

they have the wrong length, or the connection point is hidden away in a floor pocket or wall panel.

Cables are terminated at both ends for easy disconnection and re-connection, allowing use in podiums that occa-

sionally must be relocated or removed for storage.

The EasyConnect enclosure also incorporates space for seamless integration of Neets Control EcHo or SieRRa II. 

With integrated control, starting a presentation is quick and frustration-free. Simply plug in the required cables, 

press the corresponding control buttons, and your  

presentation is running in a matter of seconds!

COPYRIGHT - All information contained in this manual is the intellectual property and copyrighted material of 

Neets. All rights are reserved. You may not allow any third party access to content, information or data in this man-

ual without Neets’ express written consent.

CHANGES  - Neets reserve the right to change the specification and functions of this product without any notice.

Questions, AFTER reading this manual, can be addressed to your local dealer or:

Neets 

Langballe 4 

8700 Horsens 

Denmark 

 

by email: [email protected] or you may use our contact form at www.neets.io

  

 

Summary of Contents for 5009-005

Page 1: ...Neets EasyConnect for Neets Control Keypad Installation Manual ...

Page 2: ...cHo or SieRRa II With integrated control starting a presentation is quick and frustration free Simply plug in the required cables press the corresponding control buttons and your presentation is running in a matter of seconds COPYRIGHT All information contained in this manual is the intellectual property and copyrighted material of Neets All rights are reserved You may not allow any third party ac...

Page 3: ...use this equipment near water To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture and objects filled with liquids Unplug the product before cleaning Clean only with a dry cloth and not cleaning fluid or aerosols Such products could enter the unit and cause damage fire or electric shock Some substances may also mar the finish of the product FCC Class A Noti...

Page 4: ...s Caution Risk of electric shock Max power output 10A Check with local and state regulations before starting the installation Check all parts and equipment before installation Neets EasyConnect for Neets Control Keypad Neets EasyConnect Power ...

Page 5: ...ocedure 8 Step 1 Prepare opening 8 Step 2 Adjust depth of connector plate 8 Step 3 Evaluate cable connection procedure connect cables 9 Step 4 Insert the unit 9 Step 5 Secure the unit 9 Step 6 Complete cable terminations and connections 9 Step 7 Install Neets Control EcHo EcHo Plus or SieRRa II control module 10 Specifications 11 ...

Page 6: ...er or other device and is CE certified The depth of the connector collar panel is adjustable allowing optimum depth to suit various connector types and sizes EasyConnect is delivered with the following cables 1 x HDMI 1 x 3 5mm audio 1 x VGA 2 x Cat 6 RJ45 1 x USB A All cables are 1 7 m long with identical terminations at each end EasyConnect is available in 4 versions prepared for Neets Control K...

Page 7: ... a solid flat surface with only a small opening for lifting the cover 2 Outer flange Fits over mounting surface for clean appearance 3 Height adjustment screws Adjusts height of internal connector plate 4 Connector box Provides space for up to six AV connectors 5 Frame for Neets Control EcHo Echo Plus or SieRRa II EU control system 6 Built in AC line Outlet with either EU DK UNI or CN power socket...

Page 8: ...d to protect when cutting Cut according to markings using appropriate tools e g a jigsaw Step 2 Adjust depth of connector plate If you need a different depth of the plates inside the box you can adjust them as here bellow Remove the height adjustment screws Turn the unit and then remove back cover and the height adjust ment screws Supporting the connector plate from underneath with your fingers br...

Page 9: ...e EasyConnect unit into the opening in the mounting surface Step 5 Secure the unit Working underneath the table surface place the mounting brackets into the slots on each side of the unit Verify proper alignment before tightening the mounting screws Turn screws until the top nut contacts the mounting surface Tighten firmly NOTICE maximum thickness of table plate 60 mm Step 6 Complete cable termina...

Page 10: ... system Neets Con trol EcHo Neets Control EcHo Plus or Neets Control SieRRa II the 12 Volt DC for the control system is supplied from the Neets EasyConnect unit Remember the included in the cardboard box frame for the control system Top plate dimensions Recessed box dimensions Depth 125 mm Recessed box dimensions H e ig h t 9 7 m m W id t h 2 3 8 m m ...

Page 11: ... plate Width 252 mm 20 7 inches Depth 135 5 mm 5 3 inches Height 1 5 mm 0 06 inches Weight 2 15 kg Neets EasyConnect Power Two EU Universal DK or CH power socket Neets EasyConnect Control Direct access to AV control functions w Neets Control EcHo Echo Plus or SieRRa II integration Direct out 12V power supply Product item numbers 5009 005 EasyConnect for Neets Control Keypad EU Power Outlet 5009 00...

Page 12: ...of 12 Neets A S Langballe 4 8700 Horsens Denmark 45 75 666 099 sales neets dk www neets io Learn more at neets io Visit our website neets io for additional information about the product and the latest firmware ...

Reviews: