Doc. no#: 310-0050-001-002 R103 Manual

 

 

  

Fault 

 

Solution 

System are resuming 

factory default 

settings 

 

When pressing Switch 1 and 4 during power on the system 
will delete the current settings and resume factory default.  
This method are only intended to be used if the control 
system lock up and enter “Unexpected Error”    

 
System log file 

The Neets Control – ZULU has a log file, which contains information, warning and error that the system 
encounters during run. 
 
The log file looks like below. 

 

 
To give you the best support possible we recommend that you have access to the log file when contacting 
support.    
 
There are two ways to get access to this file: 

uSD card 

If you put the uSD card into your computer you find the log file here: Drive\System\Log.txt 
 

HTTP 

Enter the following address into your browser: http://xxx.xxx.xxx.xxx//System/Log.txt. 
xxx.xxx.xxx.xxx are the IP address of your Neets Control – ZULU. 
 
   

Remember the two“//”. 

Summary of Contents for Zulu

Page 1: ......

Page 2: ...t information or data in this manual without Neets express written consent CHANGES Neets reserve the right to change the specification and functions of this product without any notice Questions AFTER...

Page 3: ...t 2 Description 3 Connections on units 4 Technical description 5 USB 5 Power output 5 Time Battery RTC 5 RS 232 Port 6 IR RS 232 ports 6 uSD Card 6 Switch and LED 7 I O Ports 7 LAN 7 Onboard relays 8...

Page 4: ...s intelligence behind the scene The box itself is mounted over the ceiling and controlling the requested units through RS 232 IR LAN and I O Description Part number Neets Control ZULU 310 0050 RS 232...

Page 5: ...DC out 2 Fuse to enable screen mode on RELAY 1 and RELAY 2 13 3 RS 232 port 4 RS 232 or IR control out 5 230 VAC power in 6 Relay connectors 7 LED and relay test button 8 Input Output 9 Mini USB 10 S...

Page 6: ...so you do not have to connect 110 230 volt to the unit to program it BUT for long periods of testing testing your program it is recommended to connect 110 230 to the unit since the USB power is not ma...

Page 7: ...PIN 2 Tx uSD Card The uSD Card is used to storage firmware homepage and the settings Under normal operation removal of the uSD Card is not needed If needed you can copy the settings and the firmware d...

Page 8: ...d lock extra relays and so on The ports are not potential free that means you will need external relays if you need to prevent e g ground loops When used as output they are active low when the softwar...

Page 9: ...ector and therefore you must not use the RELAY 1 and RELAY 2 connectors If you do not want to use the Screen connector please remove fuses F402 and F403 SCREEN FUSES 2 5AT Read the section Controlling...

Page 10: ...e time 3 Dry contacts free to be used Cable in out of the box The Neets Control ZULU box comes with rubber globs This allows you to use any cable size you want and the taps inside the box gives you a...

Page 11: ...wrong You need the return the unit to Neets or your dealer for replacement repair Unzipping config zip file after power on If you manual have placed a project file on the uSD card the system will extr...

Page 12: ...LU has a log file which contains information warning and error that the system encounters during run The log file looks like below To give you the best support possible we recommend that you have acce...

Reviews: