English
4
Recommended installation locations *)
Area
Yes
No
Living room
X
Dining room
X
Kitchen
X
Bathroom / Toilet
X
Bedroom
X
Hallway
X
Attic
X
Basement
X
Garage
X
Boiler room
X
*) The installation requirements may differ per region.
Contact your local authorities for possible additional
requirements.
Use
LED indicator
Normal
operation
The LED indicator will
flash red once every
40 seconds.
---
Smoke/heat
detection
The alarm will
sound and the LED
indicator will flash red
continuously until the
smoke or the heat is
eliminated.
Eliminate the smoke
or the heat.
Low-battery
warning
The alarm will beep
shortly every 40
seconds and the LED
indicator will flash.
Take one of these
actions:
• Replace the battery.
• Press the test button
to pause the alarm
for 8 hours.
Defect
The alarm will beep
shortly every 40
seconds.
Replace the device.
Testing the alarm
The alarm must be tested weekly to ensure correct
operation. If the alarm test fails, replace the smoke
detector.
• Press and hold the test button for 5 seconds. The
alarm will sound.
• Release the test button.
Hush function
If the alarm sounds falsely due to cooking, the alarm can
be paused for 10 minutes by pressing the test button.
The LED indicator will flash every 8 seconds. Locate the
source of the alarm before using the hush function in
order to make sure that it is not a life-threatening
situation.
Cleaning and maintenance
Warning!
• Do not use cleaning solvents or abrasives.
• Do not clean the inside of the device.
• Do not attempt to repair the device. If the device
does not operate correctly, replace it with a new
device.
• Replace the battery immediately when the device
gives a low-battery warning. Only use the batteries
specified in the manual.
• Clean the outside of the device at least once a month.
Use a vacuum cleaner with brush nozzle to clean the
outside of the device.
Summary of Contents for WIFIDS10 Series
Page 2: ...2 1 2 3 4 5 50cm 50cm 50cm 50cm A B ...
Page 57: ......