NOM 4
3 Description
3.1 Technical data
Table 3.1 Technical data
Filtration efficiency:
• without HEPA-filter
>90%
• with HEPA-filter
>99.97%
Operating temperature
5–60 °C
Max airflow
400 m
3
/h
Filter area:
• pre-filter
3 m
2
• HEPA-filter
5.5 m
2
Power
0.37 kW
Voltage, rpm
See the type label
Frequency
50 or 60 Hz
Phase
1 ~/3 ~
Safety class
IP 55
Noise level
66.1 dB(A)
*
Weight
29 kg
Material recycling
69% of weight
* Measured according to ISO 11202
3.2 Dimensions
See
.
3.3 Area of application
The filter must only be used with oil vapour. Other
applications must be referred to the manufacturer.
Should materials containing graphite, lead or chrome
be used, the filters may have to be replaced more fre-
quently.
WARNING! Risk of fire or explosion
Do not use the filter unit to separate explosive
or fire dangerous substances.
4 Installation
See
1 Ensure the filter unit is not damaged during trans-
port.
2 Mount the filter unit with an assembly set (includ-
ing a damper) on a wall- or a machine.
• Mounting on the machine, see
B. Ensure that suit-
able fixing bolts are used and that they are se-
cure. The bolts must each stand a torque force
of minimum 720 N.
3 Put the cable from the main system through the
cable passage in the top cover and connect it to
the fan motor connection box. 1-phase or 3-phase
C and the type label of
the product.
Units intended for use with more voltages than
one are configured for the highest voltage at de-
livery. Ensure that the motor terminals are con-
figured for the supply voltage. See the inside of
the fan motor connection box lid for details.
4 Install a NOM 4 fan starter or fit a lockable safety
switch on the mains connection cable.