NOM 11
11
EN
3
Description
3.1
Area of application
The filter is to be used with oil vapour only. Other applications are to be
referred to Nederman. If materials containing graphite, lead or chrome are
used, the filters may have to be replaced more frequently.
WARNING!
Explosion risk.
Do not use the unit to separate explosive or combustible material.
3.2
Dimensions
For the dimensions of NOM 11, see Figure 1.
*Measurement depending on extension leg position.
**Internally.
***Externally.
3.3
Technical data
‘Table 3-1: Technical data’ contains technical data for NOM 11.
Table 3-1: Technical data
NOM 11
Filtration efficiency:
•
without HEPA filter
>97.5%
•
with HEPA filter
>99.97%
Operating temperature
5–60 °C
Max. air flow
1,100 m
3
/h
Filter area:
•
Main filter
8.5 m
2
•
HEPA filter
16 m
2
Power
0.75 kW
Voltage/rpm
See the type label on the motor
Frequency
50/60 Hz
Phase
1~/3~
Safety class
IP55
Noise level*
66.4 dB(A)
Weight
137 kg
Material recycling
86 percent per weight
* With silencer, measured according to ISO 11202.
4
Before installation
4.1
Delivery checks
Check the unit for any transport damage. In case of damage or parts missing,
notify the carrier and your local Nederman representative immediately.
Summary of Contents for NOM 11
Page 3: ...NOM 11 3 ...
Page 7: ...NOM 11 7 1200 Pa 3 1 6 5 4 3 2 4 ...
Page 8: ...NOM 11 8 5 ...
Page 16: ...NOM 11 EN 16 ...
Page 24: ...NOM 11 CS 24 ...
Page 32: ...NOM 11 DA 32 ...
Page 40: ...NOM 11 DE 40 ...
Page 48: ...NOM 11 ES 48 ...
Page 56: ...NOM 11 FI 56 ...
Page 64: ...NOM 11 FR 64 ...
Page 72: ...NOM 11 HU 72 ...
Page 80: ...NOM 11 IT 80 ...
Page 88: ...NOM 11 NL 88 ...
Page 112: ...NOM 11 SV 112 ...
Page 120: ...NOM 11 TR 120 ...
Page 128: ...NOM 11 ZH 128 ...
Page 129: ......
Page 130: ...www nederman com ...